Coduri de eroare Caterpillar® (CAT®) · Pe familie
1.856 de coduri de eroare documentate pe 10 modele din familia Pozator de conducte. Alege modelul sau intră direct pe cod.
1-11
Failure Mode Not Identifiable
1-2
Data Erratic, Intermittent or Incorrect
1-5
Current Below Normal
1-6
Current Above Normal
1-7
Mechanical system not responding properly
2-11
Failure Mode Not Identifiable
2-2
Data Erratic, Intermittent or Incorrect
2-5
Current Below Normal
2-6
Current Above Normal
2-7
Mechanical system not responding properly
3-11
Failure Mode Not Identifiable
3-2
Data Erratic, Intermittent or Incorrect
3-5
Current Below Normal
3-6
Current Above Normal
3-7
Mechanical system not responding properly
4-11
Failure Mode Not Identifiable
4-2
Data Erratic, Intermittent or Incorrect
4-5
Current Below Normal
4-6
Current Above Normal
4-7
Mechanical system not responding properly
5-11
Failure Mode Not Identifiable
5-2
Data Erratic, Intermittent or Incorrect
5-5
Current Below Normal
5-6
Current Above Normal
5-7
Mechanical system not responding properly
6-11
Failure Mode Not Identifiable
6-2
Data Erratic, Intermittent or Incorrect
6-5
Current Below Normal
6-6
Current Above Normal
6-7
Mechanical system not responding properly
7-5
Current Below Normal
7-6
Current Above Normal
15
17
18-5
Current Below Normal
18-6
Current Above Normal
21
22
25
27
27-3
Voltage Above Normal
27-4
Voltage Below Normal
29-2
Data Erratic, Intermittent or Incorrect
29-3
Voltage Above Normal
29-4
Voltage Below Normal
29-8
Abnormal Frequency, Pulse Width or Period
30
31
32
33
35
39
41
41-3
Voltage Above Normal
41-4
Voltage Below Normal
42
42-11
Failure Mode Not Identifiable
42-5
Current Below Normal
42-6
Current Above Normal
53
70-2
Data Erratic, Intermittent or Incorrect
70-3
Voltage Above Normal
70-4
Voltage Below Normal
75-3
Voltage Above Normal
75-4
Voltage Below Normal
85
91-0
Data Valid but Above Normal Operating Range (most severe)
91-00
Data Valid but Above Normal Operating Range (most severe)
91-02
Data Erratic, Intermittent or Incorrect
91-2
Data Erratic, Intermittent or Incorrect
91-3
Voltage Above Normal
91-4
Voltage Below Normal
91-8
Abnormal Frequency, Pulse Width or Period
94-03
Voltage Above Normal
94-04
Voltage Below Normal
94-16
Data Valid but above Normal Operating Range (moderate severity)
94-3
Voltage Above Normal
94-4
Voltage Below Normal
95
96
96-3
Voltage Above Normal
96-4
Voltage Below Normal
96-8
Abnormal Frequency, Pulse Width or Period
97
97-15
Data Valid but above Normal Operating Range (least severe)
97-16
Data Valid but above Normal Operating Range (moderate severity)
97-18
Data Valid But Below Normal Operating Range (moderate severity)
97-3
Voltage Above Normal
98
98-1
Data Valid But Below Normal Operating Range (most severe)
98-18
Data Valid But Below Normal Operating Range (moderate severity)
100
100-03
Voltage Above Normal
100-04
Voltage Below Normal
100-1
Data Valid But Below Normal Operating Range (most severe)
100-10
Abnormal rate of change
100-13
Out of Calibration
100-17
Data Valid But Below Normal Operating Range (least severe)
100-18
Data Valid But Below Normal Operating Range (moderate severity)
100-3
Voltage Above Normal
100-4
Voltage Below Normal
100-8
Abnormal Frequency, Pulse Width or Period
101-13
Out of Calibration
101-15
Data Valid but above Normal Operating Range (least severe)
101-16
Data Valid but above Normal Operating Range (moderate severity)
101-3
Voltage Above Normal
101-4
Voltage Below Normal
102-10
Abnormal rate of change
102-16
Data Valid but above Normal Operating Range (moderate severity)
102-18
Data Valid But Below Normal Operating Range (moderate severity)
102-3
Voltage Above Normal
102-4
Voltage Below Normal
105-0
Data Valid but Above Normal Operating Range (most severe)
105-15
Data Valid but above Normal Operating Range (least severe)
105-16
Data Valid but above Normal Operating Range (moderate severity)
105-3
Voltage Above Normal
105-4
Voltage Below Normal
107-15
Data Valid but above Normal Operating Range (least severe)
107-16
Data Valid but above Normal Operating Range (moderate severity)
107-3
Voltage Above Normal
107-4
Voltage Below Normal
108-21
Data Drifted Low
108-3
Voltage Above Normal
108-4
Voltage Below Normal
109-1
Data Valid But Below Normal Operating Range (most severe)
109-17
Data Valid But Below Normal Operating Range (least severe)
109-18
Data Valid But Below Normal Operating Range (moderate severity)
109-3
Voltage Above Normal
109-4
Voltage Below Normal
110-0
Data Valid but Above Normal Operating Range (most severe)
110-00
Data Valid but Above Normal Operating Range (most severe)
110-03
Voltage Above Normal
110-04
Voltage Below Normal
110-15
Data Valid but above Normal Operating Range (least severe)
110-16
Data Valid but above Normal Operating Range (moderate severity)
110-17
Data Valid But Below Normal Operating Range (least severe)
110-3
Voltage Above Normal
110-4
Voltage Below Normal
110-8
Abnormal Frequency, Pulse Width or Period
111-1
Data Valid But Below Normal Operating Range (most severe)
111/139
111-17
Data Valid But Below Normal Operating Range (least severe)
111/179
111-18
Data Valid But Below Normal Operating Range (moderate severity)
112/139
112/179
113/139
113/179
114
114/139
114/179
115/139
115/179
116
116/139
116/179
119
133
133-3
Voltage Above Normal
133-5
Current Below Normal
133-6
Current Above Normal
135
141
143
148-13
Out of Calibration
148-3
Voltage Above Normal
148-4
Voltage Below Normal
152
155
157
157-00
Data Valid but Above Normal Operating Range (most severe)
157-1
Data Valid But Below Normal Operating Range (most severe)
157-12
Bad Device or Component
157-16
Data Valid but above Normal Operating Range (moderate severity)
157-17
Data Valid But Below Normal Operating Range (least severe)
157-18
Data Valid But Below Normal Operating Range (moderate severity)
157-3
Voltage Above Normal
157-4
Voltage Below Normal
158-2
Data Erratic, Intermittent or Incorrect
159
164-00
Data Valid but Above Normal Operating Range (most severe)
164-02
Data Erratic, Intermittent or Incorrect
164-03
Voltage Above Normal
164-04
Voltage Below Normal
164-11
Failure Mode Not Identifiable
164-3
Voltage Above Normal
164-4
Voltage Below Normal
165
168
168-0
Data Valid but Above Normal Operating Range (most severe)
168-00
Data Valid but Above Normal Operating Range (most severe)
168-01
Data Valid But Below Normal Operating Range (most severe)
168-02
Data Erratic, Intermittent or Incorrect
168-1
Data Valid But Below Normal Operating Range (most severe)
168-2
Data Erratic, Intermittent or Incorrect
168-3
Voltage Above Normal
168-31
Not Available Or Condition Exists
168-4
Voltage Below Normal
171
171-4
Voltage Below Normal
172
172-03
Voltage Above Normal
172-04
Voltage Below Normal
172-3
Voltage Above Normal
172-4
Voltage Below Normal
173-18
Data Valid But Below Normal Operating Range (moderate severity)
174-0
Data Valid but Above Normal Operating Range (most severe)
174-15
Data Valid but above Normal Operating Range (least severe)
174-16
Data Valid but above Normal Operating Range (moderate severity)
174-3
Voltage Above Normal
174-4
Voltage Below Normal
175-0
Data Valid but Above Normal Operating Range (most severe)
175-03
Voltage Above Normal
175-04
Voltage Below Normal
175-15
Data Valid but above Normal Operating Range (least severe)
175-16
Data Valid but above Normal Operating Range (moderate severity)
175-3
Voltage Above Normal
175-4
Voltage Below Normal
177-3
Voltage Above Normal
177-4
Voltage Below Normal
177-8
Abnormal Frequency, Pulse Width or Period
179
181
182
185
190
190-0
Data Valid but Above Normal Operating Range (most severe)
190-02
Data Erratic, Intermittent or Incorrect
190-11
Failure Mode Not Identifiable
190-15
Data Valid but above Normal Operating Range (least severe)
190-2
Data Erratic, Intermittent or Incorrect
190-8
Abnormal Frequency, Pulse Width or Period
192
194
197
198
199
225
232
233
241
246-14
Special Instruction
246-9
Abnormal Update Rate
247-12
Bad Device or Component
247-13
Out of Calibration
247-14
Special Instruction
247-9
Abnormal Update Rate
248-09
Abnormal Update Rate
248-12
Bad Device or Component
248-2
Data Erratic, Intermittent or Incorrect
248-9
Abnormal Update Rate
253-02
Data Erratic, Intermittent or Incorrect
253-2
Data Erratic, Intermittent or Incorrect
254-04
Voltage Below Normal
254-12
Bad Device or Component
254-13
Out of Calibration
254-4
Voltage Below Normal
256
257
258
261-11
Failure Mode Not Identifiable
261-13
Out of Calibration
262-03
Voltage Above Normal
262-04
Voltage Below Normal
262-3
Voltage Above Normal
262-4
Voltage Below Normal
263-03
Voltage Above Normal
263-04
Voltage Below Normal
263-3
Voltage Above Normal
263-4
Voltage Below Normal
264
264-08
Abnormal Frequency, Pulse Width or Period
264-8
Abnormal Frequency, Pulse Width or Period
265
266-02
Data Erratic, Intermittent or Incorrect
266-2
Data Erratic, Intermittent or Incorrect
266-3
Voltage Above Normal
266-4
Voltage Below Normal
267-02
Data Erratic, Intermittent or Incorrect
267-2
Data Erratic, Intermittent or Incorrect
267-3
Voltage Above Normal
267-4
Voltage Below Normal
268
268-02
Data Erratic, Intermittent or Incorrect
268-2
Data Erratic, Intermittent or Incorrect
269-03
Voltage Above Normal
269-04
Voltage Below Normal
269-3
Voltage Above Normal
269-4
Voltage Below Normal
271-3
Voltage Above Normal
271-5
Current Below Normal
271-6
Current Above Normal
272
273-00
Data Valid but Above Normal Operating Range (most severe)
273-03
Voltage Above Normal
273-04
Voltage Below Normal
273-13
Out of Calibration
273-3
Voltage Above Normal
273-4
Voltage Below Normal
274-03
Voltage Above Normal
274-04
Voltage Below Normal
274-13
Out of Calibration
274-3
Voltage Above Normal
274-4
Voltage Below Normal
275-13
Out of Calibration
275-3
Voltage Above Normal
275-4
Voltage Below Normal
280-4
Voltage Below Normal
281
282
283
289-21
Data Drifted Low
289-3
Voltage Above Normal
289-4
Voltage Below Normal
290-3
Voltage Above Normal
290-4
Voltage Below Normal
291-05
Current Below Normal
291-06
Current Above Normal
291-3
Voltage Above Normal
291-5
Current Below Normal
291-6
Current Above Normal
296-09
Abnormal Update Rate
296-12
Bad Device or Component
296-14
Special Instruction
296-9
Abnormal Update Rate
298-2
Data Erratic, Intermittent or Incorrect
298-3
Voltage Above Normal
298-4
Voltage Below Normal
299-13
Out of Calibration
299-8
Abnormal Frequency, Pulse Width or Period
324-3
Voltage Above Normal
324-5
Current Below Normal
324-6
Current Above Normal
329
338-5
Current Below Normal
338-6
Current Above Normal
342-02
Data Erratic, Intermittent or Incorrect
342-11
Failure Mode Not Identifiable
342-2
Data Erratic, Intermittent or Incorrect
342-8
Abnormal Frequency, Pulse Width or Period
358-3
Voltage Above Normal
358-5
Current Below Normal
358-6
Current Above Normal
360
361
362
363
368-2
Data Erratic, Intermittent or Incorrect
390
396
398
411-13
Out of Calibration
411-15
Data Valid but above Normal Operating Range (least severe)
411-17
Data Valid But Below Normal Operating Range (least severe)
411-2
Data Erratic, Intermittent or Incorrect
411-3
Voltage Above Normal
411-4
Voltage Below Normal
412-15
Data Valid but above Normal Operating Range (least severe)
412-16
Data Valid but above Normal Operating Range (moderate severity)
412-3
Voltage Above Normal
412-4
Voltage Below Normal
422
441
441-0
Data Valid but Above Normal Operating Range (most severe)
441-15
Data Valid but above Normal Operating Range (least severe)
441-16
Data Valid but above Normal Operating Range (moderate severity)
441-3
Voltage Above Normal
441-4
Voltage Below Normal
442-3
Voltage Above Normal
442-4
Voltage Below Normal
443
444-05
Current Below Normal
444-06
Current Above Normal
444-3
Voltage Above Normal
444-5
Current Below Normal
444-6
Current Above Normal
445
460-21
Data Drifted Low
460-3
Voltage Above Normal
460-4
Voltage Below Normal
468-3
Voltage Above Normal
468-4
Voltage Below Normal
468-8
Abnormal Frequency, Pulse Width or Period
473-3
Voltage Above Normal
473-4
Voltage Below Normal
485-5
Current Below Normal
485-6
Current Above Normal
486-3
Voltage Above Normal
486-4
Voltage Below Normal
488
490-2
Data Erratic, Intermittent or Incorrect
490-3
Voltage Above Normal
490-4
Voltage Below Normal
491
497-13
Out of Calibration
497-3
Voltage Above Normal
497-5
Current Below Normal
497-6
Current Above Normal
498-13
Out of Calibration
498-3
Voltage Above Normal
498-5
Current Below Normal
498-6
Current Above Normal
499
516
526-5
Current Below Normal
526-6
Current Above Normal
526-7
Mechanical system not responding properly
527
539
544-08
Abnormal Frequency, Pulse Width or Period
544-2
Data Erratic, Intermittent or Incorrect
544-8
Abnormal Frequency, Pulse Width or Period
545-5
Current Below Normal
545-6
Current Above Normal
558-2
Data Erratic, Intermittent or Incorrect
562-09
Abnormal Update Rate
562-12
Bad Device or Component
562-9
Abnormal Update Rate
563
564
568
569
570
571
573-13
Out of Calibration
573-8
Abnormal Frequency, Pulse Width or Period
577
582-3
Voltage Above Normal
582-4
Voltage Below Normal
583
583-13
Out of Calibration
583-3
Voltage Above Normal
583-5
Current Below Normal
583-6
Current Above Normal
585-2
Data Erratic, Intermittent or Incorrect
588-12
Bad Device or Component
588-14
Special Instruction
588-2
Data Erratic, Intermittent or Incorrect
588-9
Abnormal Update Rate
590-12
Bad Device or Component
590-14
Special Instruction
590-2
Data Erratic, Intermittent or Incorrect
590-9
Abnormal Update Rate
593
593-31
Not Available Or Condition Exists
594
594-31
Not Available Or Condition Exists
596-12
Bad Device or Component
596-14
Special Instruction
596-9
Abnormal Update Rate
597-3
Voltage Above Normal
597-4
Voltage Below Normal
600-3
Voltage Above Normal
600-4
Voltage Below Normal
600-8
Abnormal Frequency, Pulse Width or Period
617-05
Current Below Normal
617-06
Current Above Normal
618-02
Data Erratic, Intermittent or Incorrect
618-2
Data Erratic, Intermittent or Incorrect
621-2
Data Erratic, Intermittent or Incorrect
622-2
Data Erratic, Intermittent or Incorrect
623-2
Data Erratic, Intermittent or Incorrect
623-7
Mechanical system not responding properly
625-14
Special Instruction
626-5
Current Below Normal
626-6
Current Above Normal
630
630-2
Data Erratic, Intermittent or Incorrect
631
631-2
Data Erratic, Intermittent or Incorrect
632
633
637-11
Failure Mode Not Identifiable
637-13
Out of Calibration
639-14
Special Instruction
639-9
Abnormal Update Rate
649-5
Current Below Normal
649-6
Current Above Normal
649-7
Mechanical system not responding properly
650-12
Bad Device or Component
650-2
Data Erratic, Intermittent or Incorrect
651-2
Data Erratic, Intermittent or Incorrect
651-5
Current Below Normal
651-6
Current Above Normal
651-7
Mechanical system not responding properly
652-2
Data Erratic, Intermittent or Incorrect
652-5
Current Below Normal
652-6
Current Above Normal
652-7
Mechanical system not responding properly
653-2
Data Erratic, Intermittent or Incorrect
653-5
Current Below Normal
653-6
Current Above Normal
653-7
Mechanical system not responding properly
654-2
Data Erratic, Intermittent or Incorrect
654-5
Current Below Normal
654-6
Current Above Normal
654-7
Mechanical system not responding properly
655-2
Data Erratic, Intermittent or Incorrect
655-5
Current Below Normal
655-6
Current Above Normal
655-7
Mechanical system not responding properly
656-2
Data Erratic, Intermittent or Incorrect
656-5
Current Below Normal
656-6
Current Above Normal
656-7
Mechanical system not responding properly
668-12
Bad Device or Component
671-2
Data Erratic, Intermittent or Incorrect
672-2
Data Erratic, Intermittent or Incorrect
673-2
Data Erratic, Intermittent or Incorrect
674-2
Data Erratic, Intermittent or Incorrect
675-2
Data Erratic, Intermittent or Incorrect
676-3
Voltage Above Normal
676-4
Voltage Below Normal
676-5
Current Below Normal
676-6
Current Above Normal
676-8
Abnormal Frequency, Pulse Width or Period
677-3
Voltage Above Normal
677-4
Voltage Below Normal
677-5
Current Below Normal
677-6
Current Above Normal
677-8
Abnormal Frequency, Pulse Width or Period
678
678-3
Voltage Above Normal
678-4
Voltage Below Normal
679
681-3
Voltage Above Normal
681-4
Voltage Below Normal
681-5
Current Below Normal
681-6
Current Above Normal
687
688
689-13
Out of Calibration
689-3
Voltage Above Normal
689-5
Current Below Normal
689-6
Current Above Normal
690-13
Out of Calibration
690-3
Voltage Above Normal
690-5
Current Below Normal
690-6
Current Above Normal
691-3
Voltage Above Normal
691-5
Current Below Normal
691-6
Current Above Normal
691-7
Mechanical system not responding properly
692-3
Voltage Above Normal
692-5
Current Below Normal
692-6
Current Above Normal
692-7
Mechanical system not responding properly
693-3
Voltage Above Normal
693-5
Current Below Normal
693-6
Current Above Normal
693-7
Mechanical system not responding properly
694-3
Voltage Above Normal
694-5
Current Below Normal
694-6
Current Above Normal
694-7
Mechanical system not responding properly
695
695-3
Voltage Above Normal
695-5
Current Below Normal
695-6
Current Above Normal
695-7
Mechanical system not responding properly
696
697-3
Voltage Above Normal
697-5
Current Below Normal
697-6
Current Above Normal
698-13
Out of Calibration
698-3
Voltage Above Normal
698-5
Current Below Normal
698-6
Current Above Normal
699-13
Out of Calibration
699-3
Voltage Above Normal
699-5
Current Below Normal
699-6
Current Above Normal
706
718-7
Mechanical system not responding properly
722-3
Voltage Above Normal
722-5
Current Below Normal
722-6
Current Above Normal
723-8
Abnormal Frequency, Pulse Width or Period
726-3
Voltage Above Normal
726-5
Current Below Normal
726-6
Current Above Normal
727-3
Voltage Above Normal
727-5
Current Below Normal
727-6
Current Above Normal
774-0
Data Valid but Above Normal Operating Range (most severe)
774-2
Data Erratic, Intermittent or Incorrect
774-3
Voltage Above Normal
774-4
Voltage Below Normal
774-8
Abnormal Frequency, Pulse Width or Period
779-3
Voltage Above Normal
779-4
Voltage Below Normal
788-2
Data Erratic, Intermittent or Incorrect
791
792
799-12
Bad Device or Component
811-9
Abnormal Update Rate
819-2
Data Erratic, Intermittent or Incorrect
821-3
Voltage Above Normal
821-4
Voltage Below Normal
826-3
Voltage Above Normal
826-4
Voltage Below Normal
861
875
876
878
879
882-3
Voltage Above Normal
882-5
Current Below Normal
882-6
Current Above Normal
930
931
946
947
954
960
970-31
Not Available Or Condition Exists
971-31
Not Available Or Condition Exists
991
992
993
995
997
1008
1014
1025
1026
1036
1040
1041
1044
1045
1045-8
Abnormal Frequency, Pulse Width or Period
1050
1051
1052
1053
1072-5
Current Below Normal
1072-6
Current Above Normal
1073-5
Current Below Normal
1073-6
Current Above Normal
1075-5
Current Below Normal
1075-6
Current Above Normal
1076-5
Current Below Normal
1076-6
Current Above Normal
1078-13
Out of Calibration
1078-3
Voltage Above Normal
1078-4
Voltage Below Normal
1078-8
Abnormal Frequency, Pulse Width or Period
1079-13
Out of Calibration
1079-3
Voltage Above Normal
1079-4
Voltage Below Normal
1079-8
Abnormal Frequency, Pulse Width or Period
1090-5
Current Below Normal
1090-6
Current Above Normal
1091-5
Current Below Normal
1091-6
Current Above Normal
1092
1093
1094
1095
1096
1101
1107
1109-31
Not Available Or Condition Exists
1110-31
Not Available Or Condition Exists
1121
1132
1154
1156
1170
1171
1172
1176-3
Voltage Above Normal
1176-4
Voltage Below Normal
1188-5
Current Below Normal
1188-6
Current Above Normal
1188-7
Mechanical system not responding properly
1190
1196-2
Data Erratic, Intermittent or Incorrect
1196-9
Abnormal Update Rate
1197-13
Out of Calibration
1197-3
Voltage Above Normal
1197-5
Current Below Normal
1197-6
Current Above Normal
1198-13
Out of Calibration
1198-3
Voltage Above Normal
1198-5
Current Below Normal
1198-6
Current Above Normal
1217
1218
1220
1231-14
Special Instruction
1231-9
Abnormal Update Rate
1235-14
Special Instruction
1235-9
Abnormal Update Rate
1237-31
Not Available Or Condition Exists
1239
1239-0
Data Valid but Above Normal Operating Range (most severe)
1239-14
Special Instruction
1239-9
Abnormal Update Rate
1248-5
Current Below Normal
1248-6
Current Above Normal
1250-9
Abnormal Update Rate
1251-03
Voltage Above Normal
1251-3
Voltage Above Normal
1251-4
Voltage Below Normal
1263
1264
1265
1300
1301
1302
1305
1309
1319
1326-2
Data Erratic, Intermittent or Incorrect
1327-13
Out of Calibration
1327-3
Voltage Above Normal
1327-4
Voltage Below Normal
1327-8
Abnormal Frequency, Pulse Width or Period
1328-13
Out of Calibration
1328-3
Voltage Above Normal
1328-4
Voltage Below Normal
1328-8
Abnormal Frequency, Pulse Width or Period
1329-2
Data Erratic, Intermittent or Incorrect
1330-2
Data Erratic, Intermittent or Incorrect
1347-5
Current Below Normal
1347-6
Current Above Normal
1348-5
Current Below Normal
1348-6
Current Above Normal
1363
1364
1365
1370
1377
1382-15
Data Valid but above Normal Operating Range (least severe)
1382-16
Data Valid but above Normal Operating Range (moderate severity)
1385-3
Voltage Above Normal
1385-4
Voltage Below Normal
1386
1387-1
Data Valid But Below Normal Operating Range (most severe)
1387-15
Data Valid but above Normal Operating Range (least severe)
1387-16
Data Valid but above Normal Operating Range (moderate severity)
1387-3
Voltage Above Normal
1387-4
Voltage Below Normal
1388
1389
1390
1398
1401-13
Out of Calibration
1401-3
Voltage Above Normal
1401-5
Current Below Normal
1401-6
Current Above Normal
1402-13
Out of Calibration
1402-3
Voltage Above Normal
1402-5
Current Below Normal
1402-6
Current Above Normal
1403-13
Out of Calibration
1403-3
Voltage Above Normal
1403-5
Current Below Normal
1403-6
Current Above Normal
1404-13
Out of Calibration
1404-3
Voltage Above Normal
1404-5
Current Below Normal
1404-6
Current Above Normal
1405-13
Out of Calibration
1405-3
Voltage Above Normal
1405-5
Current Below Normal
1405-6
Current Above Normal
1407
1408
1410
1425-8
Abnormal Frequency, Pulse Width or Period
1427
1430
1431
1432
1434
1441
1465
1466
1469-00
Data Valid but Above Normal Operating Range (most severe)
1469-1
Data Valid But Below Normal Operating Range (most severe)
1469-2
Data Erratic, Intermittent or Incorrect
1469-8
Abnormal Frequency, Pulse Width or Period
1470-00
Data Valid but Above Normal Operating Range (most severe)
1470-1
Data Valid But Below Normal Operating Range (most severe)
1470-2
Data Erratic, Intermittent or Incorrect
1470-8
Abnormal Frequency, Pulse Width or Period
1471-12
Bad Device or Component
1471-13
Out of Calibration
1471-3
Voltage Above Normal
1471-4
Voltage Below Normal
1471-8
Abnormal Frequency, Pulse Width or Period
1472-12
Bad Device or Component
1472-13
Out of Calibration
1472-3
Voltage Above Normal
1472-4
Voltage Below Normal
1472-8
Abnormal Frequency, Pulse Width or Period
1473-12
Bad Device or Component
1473-13
Out of Calibration
1473-3
Voltage Above Normal
1473-4
Voltage Below Normal
1473-8
Abnormal Frequency, Pulse Width or Period
1482-3
Voltage Above Normal
1482-4
Voltage Below Normal
1488-3
Voltage Above Normal
1488-5
Current Below Normal
1488-6
Current Above Normal
1503
1504
1529
1530
1551-13
Out of Calibration
1558-9
Abnormal Update Rate
1585
1589-3
Voltage Above Normal
1589-4
Voltage Below Normal
1598
1599-5
Current Below Normal
1599-6
Current Above Normal
1600-5
Current Below Normal
1600-6
Current Above Normal
1603-14
Special Instruction
1603-9
Abnormal Update Rate
1627-5
Current Below Normal
1627-6
Current Above Normal
1634-2
Data Erratic, Intermittent or Incorrect
1635-2
Data Erratic, Intermittent or Incorrect
1639-17
Data Valid But Below Normal Operating Range (least severe)
1639-2
Data Erratic, Intermittent or Incorrect
1639-9
Abnormal Update Rate
1645
1664-31
Not Available Or Condition Exists
1699-13
Out of Calibration
1699-3
Voltage Above Normal
1699-4
Voltage Below Normal
1699-8
Abnormal Frequency, Pulse Width or Period
1700-13
Out of Calibration
1700-3
Voltage Above Normal
1700-4
Voltage Below Normal
1700-8
Abnormal Frequency, Pulse Width or Period
1703-13
Out of Calibration
1703-3
Voltage Above Normal
1703-5
Current Below Normal
1703-6
Current Above Normal
1704-13
Out of Calibration
1704-3
Voltage Above Normal
1704-5
Current Below Normal
1704-6
Current Above Normal
1705-13
Out of Calibration
1705-3
Voltage Above Normal
1705-5
Current Below Normal
1705-6
Current Above Normal
1706-13
Out of Calibration
1706-3
Voltage Above Normal
1706-5
Current Below Normal
1706-6
Current Above Normal
1707-13
Out of Calibration
1707-3
Voltage Above Normal
1707-5
Current Below Normal
1707-6
Current Above Normal
1708-13
Out of Calibration
1708-3
Voltage Above Normal
1708-5
Current Below Normal
1708-6
Current Above Normal
1709
1710
1743-2
Data Erratic, Intermittent or Incorrect
1761-1
Data Valid But Below Normal Operating Range (most severe)
1761-12
Bad Device or Component
1761-17
Data Valid But Below Normal Operating Range (least severe)
1761-18
Data Valid But Below Normal Operating Range (moderate severity)
1761-2
Data Erratic, Intermittent or Incorrect
1761-3
Voltage Above Normal
1761-4
Voltage Below Normal
1779-5
Current Below Normal
1779-6
Current Above Normal
1780-5
Current Below Normal
1780-6
Current Above Normal
1785-10
Abnormal rate of change
1785-13
Out of Calibration
1785-21
Data Drifted Low
1785-3
Voltage Above Normal
1785-4
Voltage Below Normal
1797-12
Bad Device or Component
1797-3
Voltage Above Normal
1797-4
Voltage Below Normal
1834-2
Data Erratic, Intermittent or Incorrect
1835-3
Voltage Above Normal
1835-4
Voltage Below Normal
1836-3
Voltage Above Normal
1836-4
Voltage Below Normal
1870-13
Out of Calibration
1870-3
Voltage Above Normal
1870-4
Voltage Below Normal
1870-8
Abnormal Frequency, Pulse Width or Period
1884-13
Out of Calibration
1884-3
Voltage Above Normal
1884-4
Voltage Below Normal
1884-5
Current Below Normal
1884-6
Current Above Normal
1885-13
Out of Calibration
1885-3
Voltage Above Normal
1885-4
Voltage Below Normal
1885-5
Current Below Normal
1885-6
Current Above Normal
1888-14
Special Instruction
1901-5
Current Below Normal
1901-6
Current Above Normal
1901-7
Mechanical system not responding properly
1902-5
Current Below Normal
1902-6
Current Above Normal
1902-7
Mechanical system not responding properly
1903-5
Current Below Normal
1903-6
Current Above Normal
1903-7
Mechanical system not responding properly
1904-5
Current Below Normal
1904-6
Current Above Normal
1904-7
Mechanical system not responding properly
1905-5
Current Below Normal
1905-6
Current Above Normal
1905-7
Mechanical system not responding properly
1906-5
Current Below Normal
1906-6
Current Above Normal
1906-7
Mechanical system not responding properly
1922-5
Current Below Normal
1922-6
Current Above Normal
1922-7
Mechanical system not responding properly
1924-3
Voltage Above Normal
1924-4
Voltage Below Normal
1933-13
Out of Calibration
1933-3
Voltage Above Normal
1933-4
Voltage Below Normal
1933-5
Current Below Normal
1933-6
Current Above Normal
1934-13
Out of Calibration
1934-3
Voltage Above Normal
1934-4
Voltage Below Normal
1934-5
Current Below Normal
1934-6
Current Above Normal
1937-2
Data Erratic, Intermittent or Incorrect
1960-9
Abnormal Update Rate
2112
2113-3
Voltage Above Normal
2113-4
Voltage Below Normal
2121-2
Data Erratic, Intermittent or Incorrect
2121-7
Mechanical system not responding properly
2122-2
Data Erratic, Intermittent or Incorrect
2122-7
Mechanical system not responding properly
2126
2131
2131-3
Voltage Above Normal
2131-4
Voltage Below Normal
2132
2133
2143
2143-9
Abnormal Update Rate
2165
2180
2204-13
Out of Calibration
2204-3
Voltage Above Normal
2204-4
Voltage Below Normal
2204-8
Abnormal Frequency, Pulse Width or Period
2205-13
Out of Calibration
2205-3
Voltage Above Normal
2205-4
Voltage Below Normal
2205-8
Abnormal Frequency, Pulse Width or Period
2211-13
Out of Calibration
2211-3
Voltage Above Normal
2211-4
Voltage Below Normal
2211-5
Current Below Normal
2211-6
Current Above Normal
2212-13
Out of Calibration
2212-3
Voltage Above Normal
2212-4
Voltage Below Normal
2212-5
Current Below Normal
2212-6
Current Above Normal
2225-3
Voltage Above Normal
2225-4
Voltage Below Normal
2246-5
Current Below Normal
2246-6
Current Above Normal
2247-3
Voltage Above Normal
2247-4
Voltage Below Normal
2268-3
Voltage Above Normal
2268-4
Voltage Below Normal
2268-5
Current Below Normal
2268-6
Current Above Normal
2302-3
Voltage Above Normal
2302-4
Voltage Below Normal
2305-13
Out of Calibration
2305-3
Voltage Above Normal
2305-4
Voltage Below Normal
2305-8
Abnormal Frequency, Pulse Width or Period
2348-14
Special Instruction
2348-9
Abnormal Update Rate
2357-3
Voltage Above Normal
2357-4
Voltage Below Normal
2362-13
Out of Calibration
2362-3
Voltage Above Normal
2362-5
Current Below Normal
2362-6
Current Above Normal
2417-5
Current Below Normal
2417-6
Current Above Normal
2438-3
Voltage Above Normal
2438-4
Voltage Below Normal
2440-3
Voltage Above Normal
2440-5
Current Below Normal
2440-6
Current Above Normal
2441-3
Voltage Above Normal
2441-4
Voltage Below Normal
2441-8
Abnormal Frequency, Pulse Width or Period
2452-3
Voltage Above Normal
2452-4
Voltage Below Normal
2458-13
Out of Calibration
2458-2
Data Erratic, Intermittent or Incorrect
2458-3
Voltage Above Normal
2458-4
Voltage Below Normal
2460-3
Voltage Above Normal
2460-4
Voltage Below Normal
2461-5
Current Below Normal
2461-6
Current Above Normal
2465-5
Current Below Normal
2465-6
Current Above Normal
2466-9
Abnormal Update Rate
2481-3
Voltage Above Normal
2481-4
Voltage Below Normal
2482-3
Voltage Above Normal
2482-4
Voltage Below Normal
2482-5
Current Below Normal
2482-6
Current Above Normal
2489-13
Out of Calibration
2489-5
Current Below Normal
2489-6
Current Above Normal
2490-3
Voltage Above Normal
2490-4
Voltage Below Normal
2497-3
Voltage Above Normal
2497-4
Voltage Below Normal
2500-13
Out of Calibration
2500-3
Voltage Above Normal
2500-4
Voltage Below Normal
2500-8
Abnormal Frequency, Pulse Width or Period
2526-3
Voltage Above Normal
2526-4
Voltage Below Normal
2532-3
Voltage Above Normal
2532-4
Voltage Below Normal
2533-5
Current Below Normal
2533-6
Current Above Normal
2535-5
Current Below Normal
2535-6
Current Above Normal
2602-5
Current Below Normal
2602-6
Current Above Normal
2604-5
Current Below Normal
2604-6
Current Above Normal
2606-5
Current Below Normal
2606-6
Current Above Normal
2608-5
Current Below Normal
2608-6
Current Above Normal
2610-5
Current Below Normal
2610-6
Current Above Normal
2612-5
Current Below Normal
2612-6
Current Above Normal
2630-1
Data Valid But Below Normal Operating Range (most severe)
2630-3
Voltage Above Normal
2630-4
Voltage Below Normal
2659-15
Data Valid but above Normal Operating Range (least severe)
2659-17
Data Valid But Below Normal Operating Range (least severe)
2659-2
Data Erratic, Intermittent or Incorrect
2659-7
Mechanical system not responding properly
2661-3
Voltage Above Normal
2661-4
Voltage Below Normal
2663-3
Voltage Above Normal
2663-4
Voltage Below Normal
2671-3
Voltage Above Normal
2671-5
Current Below Normal
2671-6
Current Above Normal
2679-3
Voltage Above Normal
2679-4
Voltage Below Normal
2685-2
Data Erratic, Intermittent or Incorrect
2685-8
Abnormal Frequency, Pulse Width or Period
2686-2
Data Erratic, Intermittent or Incorrect
2686-8
Abnormal Frequency, Pulse Width or Period
2687-2
Data Erratic, Intermittent or Incorrect
2687-8
Abnormal Frequency, Pulse Width or Period
2688-2
Data Erratic, Intermittent or Incorrect
2688-8
Abnormal Frequency, Pulse Width or Period
2738-3
Voltage Above Normal
2738-4
Voltage Below Normal
2754-2
Data Erratic, Intermittent or Incorrect
2755-3
Voltage Above Normal
2755-4
Voltage Below Normal
2775-3
Voltage Above Normal
2775-4
Voltage Below Normal
2791-5
Current Below Normal
2791-6
Current Above Normal
2791-7
Mechanical system not responding properly
2810-3
Voltage Above Normal
2810-4
Voltage Below Normal
2813-5
Current Below Normal
2813-6
Current Above Normal
2882-2
Data Erratic, Intermittent or Incorrect
2946-13
Out of Calibration
2946-3
Voltage Above Normal
2946-4
Voltage Below Normal
2946-8
Abnormal Frequency, Pulse Width or Period
2947-13
Out of Calibration
2947-3
Voltage Above Normal
2947-4
Voltage Below Normal
2947-6
Current Above Normal
2948-13
Out of Calibration
2948-17
Data Valid But Below Normal Operating Range (least severe)
2948-3
Voltage Above Normal
2948-4
Voltage Below Normal
2948-5
Current Below Normal
2948-6
Current Above Normal
2948-7
Mechanical system not responding properly
2949-5
Current Below Normal
2949-6
Current Above Normal
2949-7
Mechanical system not responding properly
2950-3
Voltage Above Normal
2950-4
Voltage Below Normal
2950-5
Current Below Normal
2950-6
Current Above Normal
2950-7
Mechanical system not responding properly
2951-3
Voltage Above Normal
2951-5
Current Below Normal
2951-6
Current Above Normal
2951-7
Mechanical system not responding properly
2952-3
Voltage Above Normal
2952-5
Current Below Normal
2952-6
Current Above Normal
2952-7
Mechanical system not responding properly
2953-13
Out of Calibration
2953-3
Voltage Above Normal
2953-4
Voltage Below Normal
2953-5
Current Below Normal
2953-6
Current Above Normal
2953-7
Mechanical system not responding properly
2953-8
Abnormal Frequency, Pulse Width or Period
2954-5
Current Below Normal
2954-6
Current Above Normal
2954-7
Mechanical system not responding properly
2955-5
Current Below Normal
2955-6
Current Above Normal
2955-7
Mechanical system not responding properly
2956-13
Out of Calibration
2956-3
Voltage Above Normal
2956-4
Voltage Below Normal
2956-8
Abnormal Frequency, Pulse Width or Period
2957-13
Out of Calibration
2957-3
Voltage Above Normal
2957-5
Current Below Normal
2957-6
Current Above Normal
2958-13
Out of Calibration
2958-3
Voltage Above Normal
2958-5
Current Below Normal
2958-6
Current Above Normal
2959-3
Voltage Above Normal
2959-4
Voltage Below Normal
2960-2
Data Erratic, Intermittent or Incorrect
2960-3
Voltage Above Normal
2960-4
Voltage Below Normal
2961-3
Voltage Above Normal
2961-4
Voltage Below Normal
2970-2
Data Erratic, Intermittent or Incorrect
2993-3
Voltage Above Normal
2993-4
Voltage Below Normal
2993-8
Abnormal Frequency, Pulse Width or Period
2994-3
Voltage Above Normal
2994-4
Voltage Below Normal
2994-8
Abnormal Frequency, Pulse Width or Period
3002-11
Failure Mode Not Identifiable
3002-12
Bad Device or Component
3002-5
Current Below Normal
3002-6
Current Above Normal
3031-12
Bad Device or Component
3031-16
Data Valid but above Normal Operating Range (moderate severity)
3031-18
Data Valid But Below Normal Operating Range (moderate severity)
3031-3
Voltage Above Normal
3031-4
Voltage Below Normal
3031-7
Mechanical system not responding properly
3090-20
Data Drifted High
3090-21
Data Drifted Low
3090-3
Voltage Above Normal
3090-4
Voltage Below Normal
3090-7
Mechanical system not responding properly
3096-8
Abnormal Frequency, Pulse Width or Period
3100-12
Bad Device or Component
3100-2
Data Erratic, Intermittent or Incorrect
3105-20
Data Drifted High
3105-3
Voltage Above Normal
3105-4
Voltage Below Normal
3110-5
Current Below Normal
3110-6
Current Above Normal
3111-5
Current Below Normal
3111-6
Current Above Normal
3112-5
Current Below Normal
3112-6
Current Above Normal
3118-5
Current Below Normal
3118-6
Current Above Normal
3118-8
Abnormal Frequency, Pulse Width or Period
3126-5
Current Below Normal
3126-6
Current Above Normal
3126-7
Mechanical system not responding properly
3130-12
Bad Device or Component
3130-2
Data Erratic, Intermittent or Incorrect
3130-3
Voltage Above Normal
3130-4
Voltage Below Normal
3134-12
Bad Device or Component
3134-3
Voltage Above Normal
3134-4
Voltage Below Normal
3138-12
Bad Device or Component
3180-5
Current Below Normal
3182-3
Voltage Above Normal
3182-4
Voltage Below Normal
3182-5
Current Below Normal
3182-6
Current Above Normal
3183-2
Data Erratic, Intermittent or Incorrect
3184-2
Data Erratic, Intermittent or Incorrect
3187-3
Voltage Above Normal
3187-4
Voltage Below Normal
3188-3
Voltage Above Normal
3188-4
Voltage Below Normal
3191-3
Voltage Above Normal
3191-4
Voltage Below Normal
3192-3
Voltage Above Normal
3192-4
Voltage Below Normal
3193-3
Voltage Above Normal
3193-4
Voltage Below Normal
3194-3
Voltage Above Normal
3194-4
Voltage Below Normal
3195-3
Voltage Above Normal
3195-4
Voltage Below Normal
3196-3
Voltage Above Normal
3196-4
Voltage Below Normal
3197-3
Voltage Above Normal
3197-4
Voltage Below Normal
3198-3
Voltage Above Normal
3198-4
Voltage Below Normal
3200-3
Voltage Above Normal
3200-4
Voltage Below Normal
3216-11
Failure Mode Not Identifiable
3216-12
Bad Device or Component
3216-5
Current Below Normal
3216-6
Current Above Normal
3216-7
Mechanical system not responding properly
3217-16
Data Valid but above Normal Operating Range (moderate severity)
3226-11
Failure Mode Not Identifiable
3226-12
Bad Device or Component
3226-5
Current Below Normal
3226-6
Current Above Normal
3226-7
Mechanical system not responding properly
3227-16
Data Valid but above Normal Operating Range (moderate severity)
3239-5
Current Below Normal
3239-6
Current Above Normal
3241-3
Voltage Above Normal
3241-4
Voltage Below Normal
3242-15
Data Valid but above Normal Operating Range (least severe)
3242-16
Data Valid but above Normal Operating Range (moderate severity)
3242-17
Data Valid But Below Normal Operating Range (least severe)
3242-18
Data Valid But Below Normal Operating Range (moderate severity)
3242-3
Voltage Above Normal
3242-4
Voltage Below Normal
3251-13
Out of Calibration
3251-2
Data Erratic, Intermittent or Incorrect
3251-3
Voltage Above Normal
3251-4
Voltage Below Normal
3358-13
Out of Calibration
3358-21
Data Drifted Low
3358-3
Voltage Above Normal
3358-4
Voltage Below Normal
3360-12
Bad Device or Component
3360-14
Special Instruction
3360-3
Voltage Above Normal
3360-4
Voltage Below Normal
3360-9
Abnormal Update Rate
3361-11
Failure Mode Not Identifiable
3361-5
Current Below Normal
3361-6
Current Above Normal
3361-7
Mechanical system not responding properly
3362-14
Special Instruction
3363-5
Current Below Normal
3363-6
Current Above Normal
3363-7
Mechanical system not responding properly
3372-3
Voltage Above Normal
3372-4
Voltage Below Normal
3385-13
Out of Calibration
3385-21
Data Drifted Low
3385-3
Voltage Above Normal
3385-4
Voltage Below Normal
3386-3
Voltage Above Normal
3386-4
Voltage Below Normal
3387-13
Out of Calibration
3387-2
Data Erratic, Intermittent or Incorrect
3387-3
Voltage Above Normal
3387-4
Voltage Below Normal
3391-5
Current Below Normal
3391-6
Current Above Normal
3397-12
Bad Device or Component
3397-21
Data Drifted Low
3397-3
Voltage Above Normal
3397-4
Voltage Below Normal
3405-5
Current Below Normal
3405-6
Current Above Normal
3407-3
Voltage Above Normal
3407-4
Voltage Below Normal
3409-5
Current Below Normal
3409-6
Current Above Normal
3413-5
Current Below Normal
3413-6
Current Above Normal
3427-5
Current Below Normal
3427-6
Current Above Normal
3464-13
Out of Calibration
3464-21
Data Drifted Low
3464-3
Voltage Above Normal
3464-4
Voltage Below Normal
3467-3
Voltage Above Normal
3467-5
Current Below Normal
3467-6
Current Above Normal
3468-14
Special Instruction
3468-2
Data Erratic, Intermittent or Incorrect
3468-8
Abnormal Frequency, Pulse Width or Period
3469-14
Special Instruction
3469-2
Data Erratic, Intermittent or Incorrect
3469-8
Abnormal Frequency, Pulse Width or Period
3473-31
Not Available Or Condition Exists
3474-14
Special Instruction
3474-31
Not Available Or Condition Exists
3479-5
Current Below Normal
3479-6
Current Above Normal
3480-15
Data Valid but above Normal Operating Range (least severe)
3480-16
Data Valid but above Normal Operating Range (moderate severity)
3480-17
Data Valid But Below Normal Operating Range (least severe)
3480-18
Data Valid But Below Normal Operating Range (moderate severity)
3480-3
Voltage Above Normal
3480-4
Voltage Below Normal
3482-11
Failure Mode Not Identifiable
3482-3
Voltage Above Normal
3482-4
Voltage Below Normal
3483-11
Failure Mode Not Identifiable
3483-3
Voltage Above Normal
3483-4
Voltage Below Normal
3484-5
Current Below Normal
3484-6
Current Above Normal
3485-3
Voltage Above Normal
3485-4
Voltage Below Normal
3487-13
Out of Calibration
3487-5
Current Below Normal
3487-6
Current Above Normal
3487-7
Mechanical system not responding properly
3488-3
Voltage Above Normal
3488-4
Voltage Below Normal
3493-13
Out of Calibration
3493-21
Data Drifted Low
3493-3
Voltage Above Normal
3493-4
Voltage Below Normal
3509-3
Voltage Above Normal
3509-4
Voltage Below Normal
3510-3
Voltage Above Normal
3510-4
Voltage Below Normal
3511-11
Failure Mode Not Identifiable
3511-3
Voltage Above Normal
3511-4
Voltage Below Normal
3512-3
Voltage Above Normal
3512-4
Voltage Below Normal
3512-5
Current Below Normal
3512-6
Current Above Normal
3513-3
Voltage Above Normal
3513-4
Voltage Below Normal
3516-12
Bad Device or Component
3516-15
Data Valid but above Normal Operating Range (least severe)
3516-16
Data Valid but above Normal Operating Range (moderate severity)
3516-18
Data Valid But Below Normal Operating Range (moderate severity)
3516-2
Data Erratic, Intermittent or Incorrect
3527-12
Bad Device or Component
3528-21
Data Drifted Low
3528-3
Voltage Above Normal
3528-4
Voltage Below Normal
3530-31
Not Available Or Condition Exists
3547-3
Voltage Above Normal
3563-13
Out of Calibration
3563-21
Data Drifted Low
3563-3
Voltage Above Normal
3563-4
Voltage Below Normal
3607-5
Current Below Normal
3607-6
Current Above Normal
3609-11
Failure Mode Not Identifiable
3609-12
Bad Device or Component
3609-13
Out of Calibration
3609-15
Data Valid but above Normal Operating Range (least severe)
3609-17
Data Valid But Below Normal Operating Range (least severe)
3609-18
Data Valid But Below Normal Operating Range (moderate severity)
3609-21
Data Drifted Low
3609-3
Voltage Above Normal
3609-4
Voltage Below Normal
3609-5
Current Below Normal
3609-6
Current Above Normal
3616-15
Data Valid but above Normal Operating Range (least severe)
3619-11
Failure Mode Not Identifiable
3621-11
Failure Mode Not Identifiable
3655-11
Failure Mode Not Identifiable
3655-12
Bad Device or Component
3657-2
Data Erratic, Intermittent or Incorrect
3657-3
Voltage Above Normal
3657-4
Voltage Below Normal
3659-5
Current Below Normal
3659-6
Current Above Normal
3660-5
Current Below Normal
3660-6
Current Above Normal
3661-5
Current Below Normal
3661-6
Current Above Normal
3662-5
Current Below Normal
3662-6
Current Above Normal
3663-5
Current Below Normal
3663-6
Current Above Normal
3664-5
Current Below Normal
3664-6
Current Above Normal
3666-5
Current Below Normal
3666-6
Current Above Normal
3683-3
Voltage Above Normal
3683-4
Voltage Below Normal
3695-2
Data Erratic, Intermittent or Incorrect
3696-2
Data Erratic, Intermittent or Incorrect
3697-5
Current Below Normal
3697-6
Current Above Normal
3698-5
Current Below Normal
3698-6
Current Above Normal
3703-31
Not Available Or Condition Exists
3711-31
Not Available Or Condition Exists
3712-15
Data Valid but above Normal Operating Range (least severe)
3714-31
Not Available Or Condition Exists
3715-31
Not Available Or Condition Exists
3716-31
Not Available Or Condition Exists
3717-3
Voltage Above Normal
3717-4
Voltage Below Normal
3718-3
Voltage Above Normal
3718-4
Voltage Below Normal
3719-0
Data Valid but Above Normal Operating Range (most severe)
3719-16
Data Valid but above Normal Operating Range (moderate severity)
3720-15
Data Valid but above Normal Operating Range (least severe)
3720-16
Data Valid but above Normal Operating Range (moderate severity)
3750-15
Data Valid but above Normal Operating Range (least severe)
3750-17
Data Valid But Below Normal Operating Range (least severe)
3750-18
Data Valid But Below Normal Operating Range (moderate severity)
3750-31
Not Available Or Condition Exists
3766-14
Special Instruction
3797-3
Voltage Above Normal
3797-4
Voltage Below Normal
3820-12
Bad Device or Component
3820-14
Special Instruction
3820-3
Voltage Above Normal
3820-4
Voltage Below Normal
3820-9
Abnormal Update Rate
3821-11
Failure Mode Not Identifiable
3821-5
Current Below Normal
3821-6
Current Above Normal
3821-7
Mechanical system not responding properly
3822-5
Current Below Normal
3822-6
Current Above Normal
3837-13
Out of Calibration
3837-17
Data Valid But Below Normal Operating Range (least severe)
3837-21
Data Drifted Low
3837-3
Voltage Above Normal
3837-4
Voltage Below Normal
3838-5
Current Below Normal
3838-6
Current Above Normal
3862-5
Current Below Normal
3862-6
Current Above Normal
3862-7
Mechanical system not responding properly
3956-3
Voltage Above Normal
3956-4
Voltage Below Normal
3965-5
Current Below Normal
3965-6
Current Above Normal
3966-5
Current Below Normal
3966-6
Current Above Normal
4077-15
Data Valid but above Normal Operating Range (least severe)
4077-16
Data Valid but above Normal Operating Range (moderate severity)
4077-17
Data Valid But Below Normal Operating Range (least severe)
4077-18
Data Valid But Below Normal Operating Range (moderate severity)
4077-3
Voltage Above Normal
4077-4
Voltage Below Normal
4212-13
Out of Calibration
4212-5
Current Below Normal
4212-6
Current Above Normal
4214-5
Current Below Normal
4214-6
Current Above Normal
4215-3
Voltage Above Normal
4215-31
Not Available Or Condition Exists
4215-4
Voltage Below Normal
4265-5
Current Below Normal
4301-3
Voltage Above Normal
4301-4
Voltage Below Normal
4301-5
Current Below Normal
4301-6
Current Above Normal
4334-16
Data Valid but above Normal Operating Range (moderate severity)
4334-18
Data Valid But Below Normal Operating Range (moderate severity)
4334-20
Data Drifted High
4334-21
Data Drifted Low
4334-3
Voltage Above Normal
4334-4
Voltage Below Normal
4334-7
Mechanical system not responding properly
4337-8
Abnormal Frequency, Pulse Width or Period
4354-5
Current Below Normal
4354-6
Current Above Normal
4355-5
Current Below Normal
4355-6
Current Above Normal
4356-5
Current Below Normal
4356-6
Current Above Normal
4360-16
Data Valid but above Normal Operating Range (moderate severity)
4360-17
Data Valid But Below Normal Operating Range (least severe)
4360-18
Data Valid But Below Normal Operating Range (moderate severity)
4360-20
Data Drifted High
4360-3
Voltage Above Normal
4360-4
Voltage Below Normal
4364-18
Data Valid But Below Normal Operating Range (moderate severity)
4364-2
Data Erratic, Intermittent or Incorrect
4365-2
Data Erratic, Intermittent or Incorrect
4365-8
Abnormal Frequency, Pulse Width or Period
4366-2
Data Erratic, Intermittent or Incorrect
4366-8
Abnormal Frequency, Pulse Width or Period
4367-2
Data Erratic, Intermittent or Incorrect
4367-8
Abnormal Frequency, Pulse Width or Period
4368-2
Data Erratic, Intermittent or Incorrect
4368-8
Abnormal Frequency, Pulse Width or Period
4369-3
Voltage Above Normal
4369-5
Current Below Normal
4369-6
Current Above Normal
4371-3
Voltage Above Normal
4371-5
Current Below Normal
4371-6
Current Above Normal
4372-3
Voltage Above Normal
4372-5
Current Below Normal
4372-6
Current Above Normal
4373-13
Out of Calibration
4373-3
Voltage Above Normal
4373-5
Current Below Normal
4373-6
Current Above Normal
4374-13
Out of Calibration
4374-3
Voltage Above Normal
4374-5
Current Below Normal
4374-6
Current Above Normal
4374-8
Abnormal Frequency, Pulse Width or Period
4375-13
Out of Calibration
4375-3
Voltage Above Normal
4375-5
Current Below Normal
4375-6
Current Above Normal
4376-13
Out of Calibration
4376-3
Voltage Above Normal
4376-5
Current Below Normal
4376-6
Current Above Normal
4376-7
Mechanical system not responding properly
4377-12
Bad Device or Component
4377-3
Voltage Above Normal
4377-5
Current Below Normal
4377-6
Current Above Normal
4378-3
Voltage Above Normal
4378-5
Current Below Normal
4378-6
Current Above Normal
4379-3
Voltage Above Normal
4379-4
Voltage Below Normal
4379-8
Abnormal Frequency, Pulse Width or Period
4380-2
Data Erratic, Intermittent or Incorrect
4380-3
Voltage Above Normal
4380-4
Voltage Below Normal
4380-8
Abnormal Frequency, Pulse Width or Period
4512-3
Voltage Above Normal
4512-5
Current Below Normal
4512-6
Current Above Normal
4513-3
Voltage Above Normal
4513-6
Current Above Normal
4519-3
Voltage Above Normal
4519-4
Voltage Below Normal
4546-3
Voltage Above Normal
4546-4
Voltage Below Normal
4547-3
Voltage Above Normal
4547-4
Voltage Below Normal
4592-2
Data Erratic, Intermittent or Incorrect
4624-13
Out of Calibration
4625-13
Out of Calibration
4648-3
Voltage Above Normal
4648-4
Voltage Below Normal
4765-17
Data Valid But Below Normal Operating Range (least severe)
4765-3
Voltage Above Normal
4765-4
Voltage Below Normal
4783-12
Bad Device or Component
4783-21
Data Drifted Low
4783-3
Voltage Above Normal
4783-4
Voltage Below Normal
4792-31
Not Available Or Condition Exists
4825-3
Voltage Above Normal
4825-4
Voltage Below Normal
5246-0
Data Valid but Above Normal Operating Range (most severe)
5246-15
Data Valid but above Normal Operating Range (least severe)
5246-16
Data Valid but above Normal Operating Range (moderate severity)
5276-5
Current Below Normal
5276-6
Current Above Normal
5298-17
Data Valid But Below Normal Operating Range (least severe)
5392-31
Not Available Or Condition Exists
5423-5
Current Below Normal
5423-6
Current Above Normal
5424-5
Current Below Normal
5424-6
Current Above Normal
5425-5
Current Below Normal
5425-6
Current Above Normal
5480-16
Data Valid but above Normal Operating Range (moderate severity)
5491-5
Current Below Normal
5491-6
Current Above Normal
5562-1
Data Valid But Below Normal Operating Range (most severe)
5571-0
Data Valid but Above Normal Operating Range (most severe)
5576-14
Special Instruction
5576-2
Data Erratic, Intermittent or Incorrect
5576-8
Abnormal Frequency, Pulse Width or Period
5577-14
Special Instruction
5577-2
Data Erratic, Intermittent or Incorrect
5577-8
Abnormal Frequency, Pulse Width or Period
5578-21
Data Drifted Low
5578-3
Voltage Above Normal
5578-4
Voltage Below Normal
5580-0
Data Valid but Above Normal Operating Range (most severe)
5580-16
Data Valid but above Normal Operating Range (moderate severity)
5580-17
Data Valid But Below Normal Operating Range (least severe)
5580-18
Data Valid But Below Normal Operating Range (moderate severity)
5580-21
Data Drifted Low
5580-3
Voltage Above Normal
5580-4
Voltage Below Normal
5584-15
Data Valid but above Normal Operating Range (least severe)
5584-16
Data Valid but above Normal Operating Range (moderate severity)
5585-17
Data Valid But Below Normal Operating Range (least severe)
5588-14
Special Instruction
5625-3
Voltage Above Normal
5625-4
Voltage Below Normal
5629-31
Not Available Or Condition Exists
5706-5
Current Below Normal
5706-6
Current Above Normal
5758-11
Failure Mode Not Identifiable
5759-11
Failure Mode Not Identifiable
5798-7
Mechanical system not responding properly
5856-14
Special Instruction
5856-9
Abnormal Update Rate
5965-5
Current Below Normal
5965-6
Current Above Normal
5966-5
Current Below Normal
5966-6
Current Above Normal
6309-5
Current Below Normal
6309-6
Current Above Normal
6322-31
Not Available Or Condition Exists
6588-31
Not Available Or Condition Exists
7105-31
Not Available Or Condition Exists
7343-31
Not Available Or Condition Exists
7440-31
Not Available Or Condition Exists
7441-3
Voltage Above Normal
7441-4
Voltage Below Normal
Acceleration Is Poor or Throttle Response Is Poor
Air Inlet Heater Does Not Perform Additional Heating Cycles That Are Requested
Air Inlet Heater Does Not Turn Off
Air Inlet Heater Does Not Turn On
Air Inlet Heater Performs Additional Heating Cycles That Are Not Requested
Alert Indicator Is Always Flashing
Alert Indicator Never Flashes
Alternator - Charging Problem
Alternator (Charging Problem and/or Noisy Operation)
Alternator - Noisy Operation
Alternator Noise
Alternator Problem
Alternator Problem (Charging Problem and/or Noisy Operation)
Alternator Will Not Charge
ARD Combustion Supply Air Pressure Is Low
ARD Failed to Ignite
ARD Fuel Pressure Is High
ARD Fuel Pressure Is Low
ARD Is Disabled
ARD Loss of Combustion
ARD Temperature Is Low
Backup Alarm Always Off
Backup Alarm Always On
Backup Alarm Does Not Function
Battery
Battery Problem
Blade Control Lever Does Not Stay in Float Position
Brake Does Not Engage
Brake Does Not Release
Brake System
Can Not Reach Top Engine RPM
Charging System
Clean Emissions Module Has High Oxygen Level
Codes that Inhibit Operation of Aftertreatment System
Coolant Contains Fuel
Coolant Contains Oil
Coolant in Engine Oil
Coolant Level Is Low
Coolant Pressure Is Low
Coolant Temperature Is High
Coolant Temperature Is Low
Coolant Temperature Is Too High
Cooling Fan Is Always ON
Crankcase Breather Ejects Oil
Crankcase Fumes Disposal Tube Has Oil Draining
Crankcase Pressure Is High
Crankcase Pressure Is Low
Cylinder Is Noisy
DEF Control Module Temperature Is High
DEF Does Not Purge
DEF Module Does Not Respond
DEF Pressure Does Not Respond
DEF Pressure Is High
DEF Pressure Is Low
DEF Tank Level Is Low
DEF Tank Temperature Is High
DEF Tank Temperature Is Low
DEF Temperature Is Low
Desulfation Is Frequent
Diagnostics and Events Not Available
Diesel Oxidation Catalyst Has Incorrect Inlet Temperature
Diesel Oxidation Catalyst Has Low Conversion Efficiency
Diesel Particulate Filter Collects Excessive Soot
Diesel Particulate Filter Collects Excessive Soot (If Equipped)
Diesel Particulate Filter Has Changed Regeneration Interval
Diesel Particulate Filter Has High Ash Load
Diesel Particulate Filter Has High Inlet Pressure
Diesel Particulate Filter Has Low Inlet Pressure
Diesel Particulate Filter Temperature Is High
Diesel Particulate Filter Temperature Is Low
Diesel Particulate Filter Temperature Is Low (If Equipped)
ECM Does Not Communicate with Other Modules
ECM Does Not Communicate with User Interface
ECM Will Not Accept Factory Passwords
ECM Will Not Communicate with Other Systems or Display Modules
Electronic Service Tool Does Not Communicate
Electronic Service Tool Does Not Communicate with ECM
Electronic Service Tool Will Not Communicate with ECM
Engine Cranks but Does Not Start
Engine Cranks but Will Not Start
Engine Does Not Crank
Engine Does Not Crank with Starting Motor On and Pinion Engaging Ring Gear
Engine Has Early Wear
Engine Has Mechanical Noise (Knock)
Engine Misfires, Runs Rough or Is Unstable
Engine Oil in Cooling System
Engine Oil in Exhaust System
Engine Oil Temperature Is Too High
Engine Overcrank Occurrence
Engine Overspeeds
Engine Shutdown Occurrence
Engine Shutdown Occurs Intermittently
Engine Shutdown While Idling
Engine Speed Does Not Change
Engine Stalls at Low RPM
Engine Top Speed Is Not Obtained
Engine Vibration
Engine Vibration Is Excessive
Engine Will Not Crank
Excessive Black Smoke
Excessive Engine Oil Consumption
Excessive Fuel Consumption
Excessive Valve Lash
Excessive White Smoke
Exhaust Has Excessive Black Smoke
Exhaust Has Excessive White Smoke
Exhaust System Contains Coolant
Exhaust System Contains Fuel
Exhaust System Contains Oil
Exhaust Temperature Is High
Exhaust Temperature Is Too High
Fast Fill Fuel System
Fuel Consumption Is Excessive
Fuel Contains Water
Fuel Dilution of Engine Oil
Fuel Filter Is Restricted
Fuel in Cooling System
Fueling Nozzle Leaks (Fast Fill Fuel)
Fueling Nozzle Shuts Off Prematurely (Fast Fill Fuel)
Fuel Level Sender
Fuel Pressure Is High
Fuel Pressure Is Low
Fuel Pressure Problem
Fuel Rail Pressure Is Low
Fuel Rail Pressure Is Low While Cranking
Fuel Rail Pressure Leakage Is High
Fuel Rail Pressure Problem
Fuel System Water Separator Has Water
Fuel Tank Overfills (Fast Fill Fuel)
Fuel Tank Underfills (Fast Fill Fuel)
Fuel Temperature Is High
Harness Code
HVAC, Air Conditioning System
HVAC, Condensate Drainage System
HVAC, Control System
HVAC, General Troubleshooting
HVAC, Heating System
HVAC, Required Tools
HVAC, Visual Inspection
Hydraulic Fan Does Not Function
Hydraulic Fan Does Not Shut Off
Hydraulic Fan System
Hydraulic System Oil Contains Air
Hydraulic System Oil Level Is Low
Hydraulic System Oil Temperature Is High
Idle Speed Is High
Implement Cycle Time Is Fast
Implement Cycle Time Is Slow
Implement Droops Before Raising
Implement System
Indicator Lamp Problem
Inlet Air Is Restricted
Intake Manifold Air Pressure Is High
Intake Manifold Air Pressure Is Low
Intake Manifold Air Temperature Is High
Intermittent Engine Shutdown
Intermittent Low Power or Power Cutout
Low Engine Oil Pressure
Low Power/Poor or No Response to Throttle
Machine Movement
Mechanical Noise (Knock) in Engine
Noise Coming from Cylinder
NOx Conversion Is Low
NRS Exhaust Gas Temperature Is High
NRS Mass Flow Rate Problem
Oil Consumption Is Excessive
Oil Contains Coolant
Oil Contains Fuel
Oil Level Is Low
Oil Pressure Is Low
Oil Temperature Is High
Operating Hours Discrepancy
Pinion Continues to Engage after Engine Starts
Pinion Does Not Engage Ring Gear
Poor Acceleration or Response
Position Reports Not Available
Power Is Intermittently Low or Power Cutout Is Intermittent
Power Supply Circuit of Electronic Control Module
Power Train Oil
Power Train Oil Contains Air
Power Train Oil Temperature Is High
Pulse Width Modulated Sensor
Quick Left Turn Does Not Function
Quick Right Turn Does Not Function
Reporting Interval Erratic
Reports and Messages Not Available
SCR Catalyst Has Incorrect Inlet Temperature
SCR Warning System Problem
Sensor Dynamic Operation
Sensor Signal Voltage
Starting Motor Continues to Operate after Start Switch Has Been Released
Starting Motor Does Not Turn or Turns Slowly
Steering Clutch
Steering System
Switch Circuits
Temperature Sender
Transmission
Transmission Clutch
Transmission Does Not Downshift
Transmission Does Not Upshift
Troubleshooting
Valve Lash Is Excessive
Valve Rotator or Spring Lock Is Free
Winch System