Coduri de eroare Caterpillar® (CAT®) · Pe utilaj
658 de coduri de eroare documentate pentru CB-66B Vibratory Compactor (familia Compactor de asfaltare). Alege codul de pe afișaj pentru diagnostic și piese.
1-2
Data Erratic, Intermittent or Incorrect
1-5
Current Below Normal
1-6
Current Above Normal
2-2
Data Erratic, Intermittent or Incorrect
2-5
Current Below Normal
2-6
Current Above Normal
3-2
Data Erratic, Intermittent or Incorrect
3-5
Current Below Normal
3-6
Current Above Normal
4-2
Data Erratic, Intermittent or Incorrect
4-5
Current Below Normal
4-6
Current Above Normal
5-5
Current Below Normal
5-6
Current Above Normal
6-5
Current Below Normal
6-6
Current Above Normal
7-5
Current Below Normal
7-6
Current Above Normal
18-5
Current Below Normal
18-6
Current Above Normal
27-3
Voltage Above Normal
27-4
Voltage Below Normal
29-2
Data Erratic, Intermittent or Incorrect
29-3
Voltage Above Normal
29-4
Voltage Below Normal
29-8
Abnormal Frequency, Pulse Width or Period
41-3
Voltage Above Normal
41-4
Voltage Below Normal
70-2
Data Erratic, Intermittent or Incorrect
91-0
Data Valid but Above Normal Operating Range (most severe)
91-2
Data Erratic, Intermittent or Incorrect
91-3
Voltage Above Normal
91-4
Voltage Below Normal
91-8
Abnormal Frequency, Pulse Width or Period
96-3
Voltage Above Normal
96-4
Voltage Below Normal
97-15
Data Valid but above Normal Operating Range (least severe)
97-16
Data Valid but above Normal Operating Range (moderate severity)
97-3
Voltage Above Normal
98-1
Data Valid But Below Normal Operating Range (most severe)
98-18
Data Valid But Below Normal Operating Range (moderate severity)
100-1
Data Valid But Below Normal Operating Range (most severe)
100-17
Data Valid But Below Normal Operating Range (least severe)
100-18
Data Valid But Below Normal Operating Range (moderate severity)
100-3
Voltage Above Normal
100-4
Voltage Below Normal
102-16
Data Valid but above Normal Operating Range (moderate severity)
102-18
Data Valid But Below Normal Operating Range (moderate severity)
105-0
Data Valid but Above Normal Operating Range (most severe)
105-15
Data Valid but above Normal Operating Range (least severe)
105-16
Data Valid but above Normal Operating Range (moderate severity)
105-3
Voltage Above Normal
105-4
Voltage Below Normal
107-15
Data Valid but above Normal Operating Range (least severe)
107-16
Data Valid but above Normal Operating Range (moderate severity)
107-3
Voltage Above Normal
107-4
Voltage Below Normal
108-3
Voltage Above Normal
108-4
Voltage Below Normal
110-0
Data Valid but Above Normal Operating Range (most severe)
110-15
Data Valid but above Normal Operating Range (least severe)
110-16
Data Valid but above Normal Operating Range (moderate severity)
110-3
Voltage Above Normal
110-4
Voltage Below Normal
111-1
Data Valid But Below Normal Operating Range (most severe)
111-17
Data Valid But Below Normal Operating Range (least severe)
111-18
Data Valid But Below Normal Operating Range (moderate severity)
157-12
Bad Device or Component
157-16
Data Valid but above Normal Operating Range (moderate severity)
157-18
Data Valid But Below Normal Operating Range (moderate severity)
157-3
Voltage Above Normal
157-4
Voltage Below Normal
168-0
Data Valid but Above Normal Operating Range (most severe)
168-1
Data Valid But Below Normal Operating Range (most severe)
168-17
Data Valid But Below Normal Operating Range (least severe)
168-2
Data Erratic, Intermittent or Incorrect
168-3
Voltage Above Normal
168-31
Not Available Or Condition Exists
168-4
Voltage Below Normal
171
171-4
Voltage Below Normal
172-3
Voltage Above Normal
172-4
Voltage Below Normal
174-16
Data Valid but above Normal Operating Range (moderate severity)
174-3
Voltage Above Normal
174-4
Voltage Below Normal
190-0
Data Valid but Above Normal Operating Range (most severe)
190-15
Data Valid but above Normal Operating Range (least severe)
190-8
Abnormal Frequency, Pulse Width or Period
198
225
232
246-14
Special Instruction
246-9
Abnormal Update Rate
247-13
Out of Calibration
247-14
Special Instruction
247-9
Abnormal Update Rate
248-9
Abnormal Update Rate
253-2
Data Erratic, Intermittent or Incorrect
261-11
Failure Mode Not Identifiable
262-3
Voltage Above Normal
262-4
Voltage Below Normal
264
265
266-3
Voltage Above Normal
266-4
Voltage Below Normal
267-3
Voltage Above Normal
267-4
Voltage Below Normal
268-2
Data Erratic, Intermittent or Incorrect
289-3
Voltage Above Normal
289-4
Voltage Below Normal
291-5
Current Below Normal
291-6
Current Above Normal
296-14
Special Instruction
296-9
Abnormal Update Rate
342-8
Abnormal Frequency, Pulse Width or Period
360
361
362
363
390
396
398
411-13
Out of Calibration
411-2
Data Erratic, Intermittent or Incorrect
411-3
Voltage Above Normal
411-4
Voltage Below Normal
412-15
Data Valid but above Normal Operating Range (least severe)
412-16
Data Valid but above Normal Operating Range (moderate severity)
412-3
Voltage Above Normal
412-4
Voltage Below Normal
441
441-0
Data Valid but Above Normal Operating Range (most severe)
441-15
Data Valid but above Normal Operating Range (least severe)
441-16
Data Valid but above Normal Operating Range (moderate severity)
441-3
Voltage Above Normal
441-4
Voltage Below Normal
444-5
Current Below Normal
444-6
Current Above Normal
445
460-3
Voltage Above Normal
460-4
Voltage Below Normal
485-5
Current Below Normal
485-6
Current Above Normal
486-3
Voltage Above Normal
486-4
Voltage Below Normal
499
526-5
Current Below Normal
526-6
Current Above Normal
539
558-2
Data Erratic, Intermittent or Incorrect
582-3
Voltage Above Normal
582-4
Voltage Below Normal
583
587-14
Special Instruction
588-14
Special Instruction
588-9
Abnormal Update Rate
593-31
Not Available Or Condition Exists
594-31
Not Available Or Condition Exists
600-3
Voltage Above Normal
600-4
Voltage Below Normal
619-5
Current Below Normal
619-6
Current Above Normal
626-5
Current Below Normal
626-6
Current Above Normal
630-2
Data Erratic, Intermittent or Incorrect
631-2
Data Erratic, Intermittent or Incorrect
637-11
Failure Mode Not Identifiable
639-14
Special Instruction
639-8
Abnormal Frequency, Pulse Width or Period
639-9
Abnormal Update Rate
649-5
Current Below Normal
649-6
Current Above Normal
649-7
Mechanical system not responding properly
651-2
Data Erratic, Intermittent or Incorrect
651-5
Current Below Normal
651-6
Current Above Normal
652-2
Data Erratic, Intermittent or Incorrect
652-5
Current Below Normal
652-6
Current Above Normal
653-2
Data Erratic, Intermittent or Incorrect
653-5
Current Below Normal
653-6
Current Above Normal
654-2
Data Erratic, Intermittent or Incorrect
654-5
Current Below Normal
654-6
Current Above Normal
655-5
Current Below Normal
655-6
Current Above Normal
656-5
Current Below Normal
656-6
Current Above Normal
676-5
Current Below Normal
676-6
Current Above Normal
677-5
Current Below Normal
677-6
Current Above Normal
678
678-3
Voltage Above Normal
678-4
Voltage Below Normal
703-14
Special Instruction
723-8
Abnormal Frequency, Pulse Width or Period
741-13
Out of Calibration
741-5
Current Below Normal
741-6
Current Above Normal
774-0
Data Valid but Above Normal Operating Range (most severe)
774-2
Data Erratic, Intermittent or Incorrect
774-3
Voltage Above Normal
774-4
Voltage Below Normal
774-8
Abnormal Frequency, Pulse Width or Period
818-14
Special Instruction
861
878
930
931
946
947
954
960
970-31
Not Available Or Condition Exists
995
1014
1044
1045
1071-14
Special Instruction
1075-5
Current Below Normal
1075-6
Current Above Normal
1076-5
Current Below Normal
1076-6
Current Above Normal
1092
1109-31
Not Available Or Condition Exists
1110-31
Not Available Or Condition Exists
1121
1132
1171
1172
1176-3
Voltage Above Normal
1176-4
Voltage Below Normal
1188-5
Current Below Normal
1188-6
Current Above Normal
1196-2
Data Erratic, Intermittent or Incorrect
1196-9
Abnormal Update Rate
1217
1231-9
Abnormal Update Rate
1235-14
Special Instruction
1235-9
Abnormal Update Rate
1239-0
Data Valid but Above Normal Operating Range (most severe)
1263
1264
1265
1309
1319
1364
1365
1370
1377
1382-15
Data Valid but above Normal Operating Range (least severe)
1382-16
Data Valid but above Normal Operating Range (moderate severity)
1389
1398
1407
1408
1410
1431
1432
1441
1470-14
Special Instruction
1551-13
Out of Calibration
1585
1593-11
Failure Mode Not Identifiable
1593-5
Current Below Normal
1593-8
Abnormal Frequency, Pulse Width or Period
1594-11
Failure Mode Not Identifiable
1594-5
Current Below Normal
1594-8
Abnormal Frequency, Pulse Width or Period
1598
1603-14
Special Instruction
1603-9
Abnormal Update Rate
1611-7
Mechanical system not responding properly
1614-0
Data Valid but Above Normal Operating Range (most severe)
1619-14
Special Instruction
1627-5
Current Below Normal
1627-6
Current Above Normal
1634-2
Data Erratic, Intermittent or Incorrect
1635-2
Data Erratic, Intermittent or Incorrect
1638-15
Data Valid but above Normal Operating Range (least severe)
1638-16
Data Valid but above Normal Operating Range (moderate severity)
1638-3
Voltage Above Normal
1638-4
Voltage Below Normal
1639-2
Data Erratic, Intermittent or Incorrect
1639-9
Abnormal Update Rate
1645
1664-31
Not Available Or Condition Exists
1713-17
Data Valid But Below Normal Operating Range (least severe)
1713-18
Data Valid But Below Normal Operating Range (moderate severity)
1714-14
Special Instruction
1714-2
Data Erratic, Intermittent or Incorrect
1743-2
Data Erratic, Intermittent or Incorrect
1756-14
Special Instruction
1761-1
Data Valid But Below Normal Operating Range (most severe)
1761-12
Bad Device or Component
1761-17
Data Valid But Below Normal Operating Range (least severe)
1761-18
Data Valid But Below Normal Operating Range (moderate severity)
1761-2
Data Erratic, Intermittent or Incorrect
1785-13
Out of Calibration
1785-3
Voltage Above Normal
1785-4
Voltage Below Normal
1797-12
Bad Device or Component
1797-3
Voltage Above Normal
1797-4
Voltage Below Normal
1836-3
Voltage Above Normal
1836-4
Voltage Below Normal
1872-13
Out of Calibration
1872-3
Voltage Above Normal
1872-4
Voltage Below Normal
1872-8
Abnormal Frequency, Pulse Width or Period
1873-13
Out of Calibration
1873-3
Voltage Above Normal
1873-4
Voltage Below Normal
1873-8
Abnormal Frequency, Pulse Width or Period
1874-13
Out of Calibration
1874-5
Current Below Normal
1874-6
Current Above Normal
1875-13
Out of Calibration
1875-5
Current Below Normal
1875-6
Current Above Normal
2131-3
Voltage Above Normal
2131-4
Voltage Below Normal
2143
2165
2180
2246-5
Current Below Normal
2246-6
Current Above Normal
2247-3
Voltage Above Normal
2247-4
Voltage Below Normal
2417-5
Current Below Normal
2417-6
Current Above Normal
2452-3
Voltage Above Normal
2452-4
Voltage Below Normal
2526-3
Voltage Above Normal
2526-4
Voltage Below Normal
2630-3
Voltage Above Normal
2630-4
Voltage Below Normal
2659-7
Mechanical system not responding properly
2661-12
Bad Device or Component
2661-9
Abnormal Update Rate
2738-3
Voltage Above Normal
2738-4
Voltage Below Normal
2775-3
Voltage Above Normal
2775-4
Voltage Below Normal
2791-5
Current Below Normal
2791-6
Current Above Normal
2791-7
Mechanical system not responding properly
2808-14
Special Instruction
2808-9
Abnormal Update Rate
2882-2
Data Erratic, Intermittent or Incorrect
2923-0
Data Valid but Above Normal Operating Range (most severe)
2923-7
Mechanical system not responding properly
2925-5
Current Below Normal
2925-6
Current Above Normal
2970-2
Data Erratic, Intermittent or Incorrect
3002-11
Failure Mode Not Identifiable
3002-12
Bad Device or Component
3002-5
Current Below Normal
3002-6
Current Above Normal
3015-14
Special Instruction
3016-14
Special Instruction
3031-12
Bad Device or Component
3031-16
Data Valid but above Normal Operating Range (moderate severity)
3031-18
Data Valid But Below Normal Operating Range (moderate severity)
3031-7
Mechanical system not responding properly
3090-20
Data Drifted High
3090-21
Data Drifted Low
3090-3
Voltage Above Normal
3090-4
Voltage Below Normal
3100-12
Bad Device or Component
3100-2
Data Erratic, Intermittent or Incorrect
3105-20
Data Drifted High
3105-3
Voltage Above Normal
3105-4
Voltage Below Normal
3110-5
Current Below Normal
3110-6
Current Above Normal
3111-5
Current Below Normal
3111-6
Current Above Normal
3112-5
Current Below Normal
3112-6
Current Above Normal
3118-5
Current Below Normal
3118-6
Current Above Normal
3126-5
Current Below Normal
3126-6
Current Above Normal
3130-12
Bad Device or Component
3130-2
Data Erratic, Intermittent or Incorrect
3130-3
Voltage Above Normal
3130-4
Voltage Below Normal
3134-12
Bad Device or Component
3138-12
Bad Device or Component
3216-11
Failure Mode Not Identifiable
3216-12
Bad Device or Component
3216-5
Current Below Normal
3216-6
Current Above Normal
3216-7
Mechanical system not responding properly
3217-16
Data Valid but above Normal Operating Range (moderate severity)
3226-11
Failure Mode Not Identifiable
3226-12
Bad Device or Component
3226-5
Current Below Normal
3226-6
Current Above Normal
3226-7
Mechanical system not responding properly
3227-16
Data Valid but above Normal Operating Range (moderate severity)
3242-17
Data Valid But Below Normal Operating Range (least severe)
3242-18
Data Valid But Below Normal Operating Range (moderate severity)
3242-3
Voltage Above Normal
3242-4
Voltage Below Normal
3358-13
Out of Calibration
3358-3
Voltage Above Normal
3358-4
Voltage Below Normal
3360-14
Special Instruction
3360-3
Voltage Above Normal
3360-4
Voltage Below Normal
3360-9
Abnormal Update Rate
3361-5
Current Below Normal
3361-6
Current Above Normal
3363-5
Current Below Normal
3363-6
Current Above Normal
3372-3
Voltage Above Normal
3372-4
Voltage Below Normal
3385-13
Out of Calibration
3385-3
Voltage Above Normal
3385-4
Voltage Below Normal
3386-3
Voltage Above Normal
3386-4
Voltage Below Normal
3387-13
Out of Calibration
3387-2
Data Erratic, Intermittent or Incorrect
3387-3
Voltage Above Normal
3387-4
Voltage Below Normal
3397-12
Bad Device or Component
3397-21
Data Drifted Low
3397-3
Voltage Above Normal
3397-4
Voltage Below Normal
3405-5
Current Below Normal
3405-6
Current Above Normal
3407-3
Voltage Above Normal
3407-4
Voltage Below Normal
3467-5
Current Below Normal
3467-6
Current Above Normal
3468-14
Special Instruction
3468-2
Data Erratic, Intermittent or Incorrect
3468-8
Abnormal Frequency, Pulse Width or Period
3482-3
Voltage Above Normal
3482-4
Voltage Below Normal
3483-3
Voltage Above Normal
3483-4
Voltage Below Normal
3509-0
Data Valid but Above Normal Operating Range (most severe)
3509-1
Data Valid But Below Normal Operating Range (most severe)
3509-3
Voltage Above Normal
3509-4
Voltage Below Normal
3510-0
Data Valid but Above Normal Operating Range (most severe)
3510-1
Data Valid But Below Normal Operating Range (most severe)
3510-3
Voltage Above Normal
3510-4
Voltage Below Normal
3511-3
Voltage Above Normal
3511-4
Voltage Below Normal
3512-3
Voltage Above Normal
3512-4
Voltage Below Normal
3512-5
Current Below Normal
3512-6
Current Above Normal
3513-3
Voltage Above Normal
3513-4
Voltage Below Normal
3516-12
Bad Device or Component
3516-15
Data Valid but above Normal Operating Range (least severe)
3516-18
Data Valid But Below Normal Operating Range (moderate severity)
3516-2
Data Erratic, Intermittent or Incorrect
3528-3
Voltage Above Normal
3528-4
Voltage Below Normal
3547-3
Voltage Above Normal
3563-13
Out of Calibration
3563-3
Voltage Above Normal
3563-4
Voltage Below Normal
3607-5
Current Below Normal
3607-6
Current Above Normal
3609-11
Failure Mode Not Identifiable
3609-12
Bad Device or Component
3609-5
Current Below Normal
3609-6
Current Above Normal
3619-11
Failure Mode Not Identifiable
3621-11
Failure Mode Not Identifiable
3666-5
Current Below Normal
3666-6
Current Above Normal
3719-0
Data Valid but Above Normal Operating Range (most severe)
3719-16
Data Valid but above Normal Operating Range (moderate severity)
3820-14
Special Instruction
3820-3
Voltage Above Normal
3820-4
Voltage Below Normal
3820-9
Abnormal Update Rate
3821-5
Current Below Normal
3821-6
Current Above Normal
3838-5
Current Below Normal
3838-6
Current Above Normal
3956-3
Voltage Above Normal
3956-4
Voltage Below Normal
3965-5
Current Below Normal
3965-6
Current Above Normal
3966-5
Current Below Normal
3966-6
Current Above Normal
4056-14
Special Instruction
4212-5
Current Below Normal
4212-6
Current Above Normal
4216-13
Out of Calibration
4216-5
Current Below Normal
4216-6
Current Above Normal
4334-16
Data Valid but above Normal Operating Range (moderate severity)
4334-18
Data Valid But Below Normal Operating Range (moderate severity)
4334-20
Data Drifted High
4334-21
Data Drifted Low
4334-3
Voltage Above Normal
4334-4
Voltage Below Normal
4354-5
Current Below Normal
4354-6
Current Above Normal
4355-5
Current Below Normal
4355-6
Current Above Normal
4356-5
Current Below Normal
4356-6
Current Above Normal
4360-16
Data Valid but above Normal Operating Range (moderate severity)
4360-17
Data Valid But Below Normal Operating Range (least severe)
4360-18
Data Valid But Below Normal Operating Range (moderate severity)
4360-20
Data Drifted High
4360-3
Voltage Above Normal
4360-4
Voltage Below Normal
4364-18
Data Valid But Below Normal Operating Range (moderate severity)
4364-2
Data Erratic, Intermittent or Incorrect
4374-5
Current Below Normal
4374-6
Current Above Normal
4377-12
Bad Device or Component
4380-2
Data Erratic, Intermittent or Incorrect
4519-3
Voltage Above Normal
4519-4
Voltage Below Normal
4592-2
Data Erratic, Intermittent or Incorrect
4648-3
Voltage Above Normal
4648-4
Voltage Below Normal
4765-17
Data Valid But Below Normal Operating Range (least severe)
4765-3
Voltage Above Normal
4765-4
Voltage Below Normal
4783-12
Bad Device or Component
4783-21
Data Drifted Low
4783-3
Voltage Above Normal
4783-4
Voltage Below Normal
5246-0
Data Valid but Above Normal Operating Range (most severe)
5246-15
Data Valid but above Normal Operating Range (least severe)
5246-16
Data Valid but above Normal Operating Range (moderate severity)
5298-17
Data Valid But Below Normal Operating Range (least severe)
5392-31
Not Available Or Condition Exists
5571-0
Data Valid but Above Normal Operating Range (most severe)
5576-14
Special Instruction
5576-2
Data Erratic, Intermittent or Incorrect
5576-8
Abnormal Frequency, Pulse Width or Period
5578-3
Voltage Above Normal
5578-4
Voltage Below Normal
5580-0
Data Valid but Above Normal Operating Range (most severe)
5580-17
Data Valid But Below Normal Operating Range (least severe)
5580-18
Data Valid But Below Normal Operating Range (moderate severity)
5588-14
Special Instruction
5625-3
Voltage Above Normal
5625-4
Voltage Below Normal
5629-31
Not Available Or Condition Exists
5706-5
Current Below Normal
5706-6
Current Above Normal
5758-11
Failure Mode Not Identifiable
5759-11
Failure Mode Not Identifiable
5856-14
Special Instruction
5856-9
Abnormal Update Rate
5965-5
Current Below Normal
5965-6
Current Above Normal
5966-5
Current Below Normal
5966-6
Current Above Normal
6309-5
Current Below Normal
6309-6
Current Above Normal
6724-13
Out of Calibration
6724-5
Current Below Normal
6724-6
Current Above Normal
6725-13
Out of Calibration
6725-5
Current Below Normal
6725-6
Current Above Normal
6726-13
Out of Calibration
6726-5
Current Below Normal
6726-6
Current Above Normal
6727-13
Out of Calibration
6727-5
Current Below Normal
6727-6
Current Above Normal
6728-8
Abnormal Frequency, Pulse Width or Period
6729-8
Abnormal Frequency, Pulse Width or Period
7105-31
Not Available Or Condition Exists
7343-31
Not Available Or Condition Exists
7440-31
Not Available Or Condition Exists
7441-3
Voltage Above Normal
7441-4
Voltage Below Normal
Acceleration Is Poor or Throttle Response Is Poor
Alternator Problem
Battery Problem
Clean Emissions Module Has High Oxygen Level
Coolant Contains Oil
Coolant Level Is Low
Coolant Temperature Is High
Coolant Temperature Is Low
Crankcase Breather Ejects Oil
Crankcase Fumes Disposal Tube Has Oil Draining
Cylinder Is Noisy
DEF Pressure Does Not Respond
DEF Pressure Is High
DEF Pressure Is Low
DEF Tank Level Is Low
DEF Tank Temperature Is High
DEF Tank Temperature Is Low
Diesel Oxidation Catalyst Has Incorrect Inlet Temperature
Diesel Oxidation Catalyst Has Low Conversion Efficiency
Diesel Particulate Filter Collects Excessive Soot (If Equipped)
Diesel Particulate Filter Temperature Is Low (If Equipped)
ECM Will Not Accept Factory Passwords
Electronic Service Tool Does Not Communicate
Engine Cranks but Does Not Start
Engine Does Not Crank
Engine Has Early Wear
Engine Has Mechanical Noise (Knock)
Engine Misfires, Runs Rough or Is Unstable
Engine Overcrank Occurrence
Engine Overspeeds
Engine Shutdown Occurrence
Engine Shutdown Occurs Intermittently
Engine Stalls at Low RPM
Engine Top Speed Is Not Obtained
Engine Vibration Is Excessive
Exhaust Has Excessive Black Smoke
Exhaust Has Excessive White Smoke
Exhaust System Contains Coolant
Exhaust System Contains Oil
Fuel Consumption Is Excessive
Fuel Contains Water
Fuel Filter Is Restricted
Fuel Pressure Is Low
Fuel Pressure Problem
Fuel Rail Pressure Problem
Fuel Temperature Is High
Hydraulic System
Inlet Air Is Restricted
Intake Manifold Air Pressure Is High
Intake Manifold Air Pressure Is Low
Intake Manifold Air Temperature Is High
Machine Movement Without Request
Machine Preparation for Troubleshooting
NOx Conversion Is Low
NRS Exhaust Gas Temperature Is High
NRS Mass Flow Rate Problem
Oil Consumption Is Excessive
Oil Contains Coolant
Oil Contains Fuel
Oil Level Is Low
Oil Pressure Is Low
Power Is Intermittently Low or Power Cutout Is Intermittent
Propel System
Propel System Troubleshooting
SCR Catalyst Has Incorrect Inlet Temperature
SCR Warning System Problem
Valve Lash Is Excessive