1-2
Data Erratic, Intermittent or Incorrect
1-5
Current Below Normal
1-6
Current Above Normal
2-2
Data Erratic, Intermittent or Incorrect
2-5
Current Below Normal
2-6
Current Above Normal
3-2
Data Erratic, Intermittent or Incorrect
3-5
Current Below Normal
3-6
Current Above Normal
4-2
Data Erratic, Intermittent or Incorrect
4-5
Current Below Normal
4-6
Current Above Normal
18-5
Current Below Normal
18-6
Current Above Normal
27-3
Voltage Above Normal
27-4
Voltage Below Normal
29-2
Data Erratic, Intermittent or Incorrect
29-3
Voltage Above Normal
29-4
Voltage Below Normal
29-8
Abnormal Frequency, Pulse Width or Period
41-3
Voltage Above Normal
41-4
Voltage Below Normal
91-0
Data Valid but Above Normal Operating Range (most severe)
91-2
Data Erratic, Intermittent or Incorrect
91-3
Voltage Above Normal
91-4
Voltage Below Normal
91-8
Abnormal Frequency, Pulse Width or Period
96-3
Voltage Above Normal
96-4
Voltage Below Normal
97-15
Data Valid but above Normal Operating Range (least severe)
97-16
Data Valid but above Normal Operating Range (moderate severity)
97-3
Voltage Above Normal
98-1
Data Valid But Below Normal Operating Range (most severe)
98-18
Data Valid But Below Normal Operating Range (moderate severity)
100-1
Data Valid But Below Normal Operating Range (most severe)
100-17
Data Valid But Below Normal Operating Range (least severe)
100-18
Data Valid But Below Normal Operating Range (moderate severity)
100-3
Voltage Above Normal
100-4
Voltage Below Normal
102-16
Data Valid but above Normal Operating Range (moderate severity)
102-18
Data Valid But Below Normal Operating Range (moderate severity)
105-0
Data Valid but Above Normal Operating Range (most severe)
105-15
Data Valid but above Normal Operating Range (least severe)
105-16
Data Valid but above Normal Operating Range (moderate severity)
105-3
Voltage Above Normal
105-4
Voltage Below Normal
107-15
Data Valid but above Normal Operating Range (least severe)
107-16
Data Valid but above Normal Operating Range (moderate severity)
107-3
Voltage Above Normal
107-4
Voltage Below Normal
108-3
Voltage Above Normal
108-4
Voltage Below Normal
110-0
Data Valid but Above Normal Operating Range (most severe)
110-15
Data Valid but above Normal Operating Range (least severe)
110-16
Data Valid but above Normal Operating Range (moderate severity)
110-3
Voltage Above Normal
110-4
Voltage Below Normal
111-1
Data Valid But Below Normal Operating Range (most severe)
111-17
Data Valid But Below Normal Operating Range (least severe)
111-18
Data Valid But Below Normal Operating Range (moderate severity)
119
152-4
Voltage Below Normal
153
155
157-12
Bad Device or Component
157-16
Data Valid but above Normal Operating Range (moderate severity)
157-18
Data Valid But Below Normal Operating Range (moderate severity)
157-3
Voltage Above Normal
157-4
Voltage Below Normal
168-3
Voltage Above Normal
168-31
Not Available Or Condition Exists
168-4
Voltage Below Normal
171
172-3
Voltage Above Normal
172-4
Voltage Below Normal
174-16
Data Valid but above Normal Operating Range (moderate severity)
174-3
Voltage Above Normal
174-4
Voltage Below Normal
190-0
Data Valid but Above Normal Operating Range (most severe)
190-15
Data Valid but above Normal Operating Range (least severe)
190-8
Abnormal Frequency, Pulse Width or Period
198
225
232
247-13
Out of Calibration
247-14
Special Instruction
247-9
Abnormal Update Rate
253-2
Data Erratic, Intermittent or Incorrect
261-11
Failure Mode Not Identifiable
262-3
Voltage Above Normal
262-4
Voltage Below Normal
265
268-2
Data Erratic, Intermittent or Incorrect
282
289-3
Voltage Above Normal
289-4
Voltage Below Normal
291-5
Current Below Normal
291-6
Current Above Normal
342-8
Abnormal Frequency, Pulse Width or Period
360
361
362
363
367-4
Voltage Below Normal
368-3
Voltage Above Normal
368-4
Voltage Below Normal
390
396
398
411-13
Out of Calibration
411-2
Data Erratic, Intermittent or Incorrect
411-3
Voltage Above Normal
411-4
Voltage Below Normal
412-15
Data Valid but above Normal Operating Range (least severe)
412-16
Data Valid but above Normal Operating Range (moderate severity)
412-3
Voltage Above Normal
412-4
Voltage Below Normal
441
441-0
Data Valid but Above Normal Operating Range (most severe)
441-15
Data Valid but above Normal Operating Range (least severe)
441-16
Data Valid but above Normal Operating Range (moderate severity)
441-3
Voltage Above Normal
441-4
Voltage Below Normal
444-5
Current Below Normal
444-6
Current Above Normal
445
490
490-3
Voltage Above Normal
490-4
Voltage Below Normal
499
517-2
Data Erratic, Intermittent or Incorrect
517-3
Voltage Above Normal
517-4
Voltage Below Normal
526-5
Current Below Normal
526-6
Current Above Normal
539
558-2
Data Erratic, Intermittent or Incorrect
582-3
Voltage Above Normal
582-4
Voltage Below Normal
583
586-2
Data Erratic, Intermittent or Incorrect
586-3
Voltage Above Normal
593-31
Not Available Or Condition Exists
594-31
Not Available Or Condition Exists
597-3
Voltage Above Normal
597-4
Voltage Below Normal
597-8
Abnormal Frequency, Pulse Width or Period
600-3
Voltage Above Normal
600-4
Voltage Below Normal
623-12
Bad Device or Component
626-3
Voltage Above Normal
626-4
Voltage Below Normal
626-5
Current Below Normal
626-6
Current Above Normal
627
629-4
Voltage Below Normal
630-2
Data Erratic, Intermittent or Incorrect
631-2
Data Erratic, Intermittent or Incorrect
637-11
Failure Mode Not Identifiable
637-6
Current Above Normal
639-14
Special Instruction
639-2
Data Erratic, Intermittent or Incorrect
639-3
Voltage Above Normal
639-4
Voltage Below Normal
639-9
Abnormal Update Rate
649-5
Current Below Normal
649-6
Current Above Normal
649-7
Mechanical system not responding properly
651-2
Data Erratic, Intermittent or Incorrect
651-5
Current Below Normal
651-6
Current Above Normal
652-2
Data Erratic, Intermittent or Incorrect
652-5
Current Below Normal
652-6
Current Above Normal
653-2
Data Erratic, Intermittent or Incorrect
653-5
Current Below Normal
653-6
Current Above Normal
654-2
Data Erratic, Intermittent or Incorrect
654-5
Current Below Normal
654-6
Current Above Normal
676-5
Current Below Normal
676-6
Current Above Normal
677-5
Current Below Normal
677-6
Current Above Normal
678-3
Voltage Above Normal
678-4
Voltage Below Normal
679-3
Voltage Above Normal
679-5
Current Below Normal
679-6
Current Above Normal
702-3
Voltage Above Normal
702-4
Voltage Below Normal
723-8
Abnormal Frequency, Pulse Width or Period
740-3
Voltage Above Normal
740-5
Current Below Normal
740-6
Current Above Normal
769-3
Voltage Above Normal
769-4
Voltage Below Normal
769-8
Abnormal Frequency, Pulse Width or Period
774-0
Data Valid but Above Normal Operating Range (most severe)
774-2
Data Erratic, Intermittent or Incorrect
774-3
Voltage Above Normal
774-4
Voltage Below Normal
774-8
Abnormal Frequency, Pulse Width or Period
826-3
Voltage Above Normal
826-4
Voltage Below Normal
861
875
876
878
882-3
Voltage Above Normal
882-5
Current Below Normal
882-6
Current Above Normal
930
931
946
947
954
960
970-31
Not Available Or Condition Exists
979
995
1014
1044
1045
1075-5
Current Below Normal
1075-6
Current Above Normal
1076-5
Current Below Normal
1076-6
Current Above Normal
1092
1109-31
Not Available Or Condition Exists
1110-31
Not Available Or Condition Exists
1121
1132
1171
1172
1176-3
Voltage Above Normal
1176-4
Voltage Below Normal
1188-5
Current Below Normal
1188-6
Current Above Normal
1196-2
Data Erratic, Intermittent or Incorrect
1196-9
Abnormal Update Rate
1217
1235-14
Special Instruction
1235-9
Abnormal Update Rate
1239-0
Data Valid but Above Normal Operating Range (most severe)
1263
1264
1265
1309
1319
1359
1364
1365
1370
1373
1377
1378
1379
1382-15
Data Valid but above Normal Operating Range (least severe)
1382-16
Data Valid but above Normal Operating Range (moderate severity)
1389
1398
1401-3
Voltage Above Normal
1401-5
Current Below Normal
1401-6
Current Above Normal
1402-3
Voltage Above Normal
1402-5
Current Below Normal
1402-6
Current Above Normal
1403-3
Voltage Above Normal
1403-5
Current Below Normal
1403-6
Current Above Normal
1404-3
Voltage Above Normal
1404-5
Current Below Normal
1404-6
Current Above Normal
1405-3
Voltage Above Normal
1405-5
Current Below Normal
1405-6
Current Above Normal
1406-3
Voltage Above Normal
1406-5
Current Below Normal
1406-6
Current Above Normal
1407
1408
1410
1431
1432
1441
1442
1529-2
Data Erratic, Intermittent or Incorrect
1529-4
Voltage Below Normal
1551-13
Out of Calibration
1562-2
Data Erratic, Intermittent or Incorrect
1563-2
Data Erratic, Intermittent or Incorrect
1585
1598
1634-2
Data Erratic, Intermittent or Incorrect
1635-2
Data Erratic, Intermittent or Incorrect
1639-2
Data Erratic, Intermittent or Incorrect
1639-9
Abnormal Update Rate
1645
1664-31
Not Available Or Condition Exists
1743-2
Data Erratic, Intermittent or Incorrect
1746-0
Data Valid but Above Normal Operating Range (most severe)
1746-12
Bad Device or Component
1746-13
Out of Calibration
1746-19
Received Network Data In Erro
1746-2
Data Erratic, Intermittent or Incorrect
1746-31
Not Available Or Condition Exists
1746-7
Mechanical system not responding properly
1761-1
Data Valid But Below Normal Operating Range (most severe)
1761-12
Bad Device or Component
1761-17
Data Valid But Below Normal Operating Range (least severe)
1761-18
Data Valid But Below Normal Operating Range (moderate severity)
1761-2
Data Erratic, Intermittent or Incorrect
1785-13
Out of Calibration
1785-3
Voltage Above Normal
1785-4
Voltage Below Normal
1797-12
Bad Device or Component
1797-3
Voltage Above Normal
1797-4
Voltage Below Normal
1836-3
Voltage Above Normal
1836-4
Voltage Below Normal
2131-3
Voltage Above Normal
2131-4
Voltage Below Normal
2143
2165
2180
2236-2
Data Erratic, Intermittent or Incorrect
2236-3
Voltage Above Normal
2236-5
Current Below Normal
2236-6
Current Above Normal
2237-2
Data Erratic, Intermittent or Incorrect
2237-3
Voltage Above Normal
2237-5
Current Below Normal
2237-6
Current Above Normal
2242-2
Data Erratic, Intermittent or Incorrect
2242-3
Voltage Above Normal
2242-5
Current Below Normal
2242-6
Current Above Normal
2243-2
Data Erratic, Intermittent or Incorrect
2243-3
Voltage Above Normal
2243-5
Current Below Normal
2243-6
Current Above Normal
2244-2
Data Erratic, Intermittent or Incorrect
2244-3
Voltage Above Normal
2244-5
Current Below Normal
2244-6
Current Above Normal
2245-2
Data Erratic, Intermittent or Incorrect
2245-3
Voltage Above Normal
2245-5
Current Below Normal
2245-6
Current Above Normal
2246-5
Current Below Normal
2246-6
Current Above Normal
2417-5
Current Below Normal
2417-6
Current Above Normal
2452-3
Voltage Above Normal
2452-4
Voltage Below Normal
2526-3
Voltage Above Normal
2526-4
Voltage Below Normal
2529-2
Data Erratic, Intermittent or Incorrect
2530-2
Data Erratic, Intermittent or Incorrect
2531-2
Data Erratic, Intermittent or Incorrect
2630-3
Voltage Above Normal
2630-4
Voltage Below Normal
2659-7
Mechanical system not responding properly
2735-3
Voltage Above Normal
2735-4
Voltage Below Normal
2736-3
Voltage Above Normal
2736-4
Voltage Below Normal
2738-3
Voltage Above Normal
2738-4
Voltage Below Normal
2775-3
Voltage Above Normal
2775-4
Voltage Below Normal
2791-5
Current Below Normal
2791-6
Current Above Normal
2791-7
Mechanical system not responding properly
2858-2
Data Erratic, Intermittent or Incorrect
2882-2
Data Erratic, Intermittent or Incorrect
2970-2
Data Erratic, Intermittent or Incorrect
2977-3
Voltage Above Normal
2977-4
Voltage Below Normal
2977-7
Mechanical system not responding properly
3002-11
Failure Mode Not Identifiable
3002-12
Bad Device or Component
3002-5
Current Below Normal
3002-6
Current Above Normal
3031-12
Bad Device or Component
3031-16
Data Valid but above Normal Operating Range (moderate severity)
3031-18
Data Valid But Below Normal Operating Range (moderate severity)
3031-7
Mechanical system not responding properly
3084-3
Voltage Above Normal
3084-4
Voltage Below Normal
3090-20
Data Drifted High
3090-21
Data Drifted Low
3090-3
Voltage Above Normal
3090-4
Voltage Below Normal
3100-12
Bad Device or Component
3100-2
Data Erratic, Intermittent or Incorrect
3105-20
Data Drifted High
3105-3
Voltage Above Normal
3105-4
Voltage Below Normal
3110-5
Current Below Normal
3110-6
Current Above Normal
3111-5
Current Below Normal
3111-6
Current Above Normal
3112-5
Current Below Normal
3112-6
Current Above Normal
3118-5
Current Below Normal
3118-6
Current Above Normal
3126-5
Current Below Normal
3126-6
Current Above Normal
3130-12
Bad Device or Component
3130-2
Data Erratic, Intermittent or Incorrect
3134-12
Bad Device or Component
3138-12
Bad Device or Component
3216-11
Failure Mode Not Identifiable
3216-12
Bad Device or Component
3216-5
Current Below Normal
3216-6
Current Above Normal
3216-7
Mechanical system not responding properly
3217-16
Data Valid but above Normal Operating Range (moderate severity)
3226-11
Failure Mode Not Identifiable
3226-12
Bad Device or Component
3226-5
Current Below Normal
3226-6
Current Above Normal
3226-7
Mechanical system not responding properly
3227-16
Data Valid but above Normal Operating Range (moderate severity)
3242-17
Data Valid But Below Normal Operating Range (least severe)
3242-18
Data Valid But Below Normal Operating Range (moderate severity)
3242-3
Voltage Above Normal
3242-4
Voltage Below Normal
3358-13
Out of Calibration
3358-3
Voltage Above Normal
3358-4
Voltage Below Normal
3360-14
Special Instruction
3360-3
Voltage Above Normal
3360-4
Voltage Below Normal
3360-9
Abnormal Update Rate
3361-5
Current Below Normal
3361-6
Current Above Normal
3363-5
Current Below Normal
3363-6
Current Above Normal
3372-3
Voltage Above Normal
3372-4
Voltage Below Normal
3377-3
Voltage Above Normal
3377-4
Voltage Below Normal
3377-8
Abnormal Frequency, Pulse Width or Period
3378-3
Voltage Above Normal
3378-4
Voltage Below Normal
3378-8
Abnormal Frequency, Pulse Width or Period
3385-13
Out of Calibration
3385-3
Voltage Above Normal
3385-4
Voltage Below Normal
3386-3
Voltage Above Normal
3386-4
Voltage Below Normal
3387-13
Out of Calibration
3387-2
Data Erratic, Intermittent or Incorrect
3387-3
Voltage Above Normal
3387-4
Voltage Below Normal
3397-12
Bad Device or Component
3397-21
Data Drifted Low
3397-3
Voltage Above Normal
3397-4
Voltage Below Normal
3405-5
Current Below Normal
3405-6
Current Above Normal
3407-3
Voltage Above Normal
3407-4
Voltage Below Normal
3468-14
Special Instruction
3468-2
Data Erratic, Intermittent or Incorrect
3468-8
Abnormal Frequency, Pulse Width or Period
3482-3
Voltage Above Normal
3482-4
Voltage Below Normal
3483-3
Voltage Above Normal
3483-4
Voltage Below Normal
3509-3
Voltage Above Normal
3509-4
Voltage Below Normal
3510-3
Voltage Above Normal
3510-4
Voltage Below Normal
3511-3
Voltage Above Normal
3511-4
Voltage Below Normal
3512-3
Voltage Above Normal
3512-4
Voltage Below Normal
3512-5
Current Below Normal
3512-6
Current Above Normal
3513-3
Voltage Above Normal
3513-4
Voltage Below Normal
3516-12
Bad Device or Component
3516-15
Data Valid but above Normal Operating Range (least severe)
3516-18
Data Valid But Below Normal Operating Range (moderate severity)
3516-2
Data Erratic, Intermittent or Incorrect
3528-3
Voltage Above Normal
3528-4
Voltage Below Normal
3547-3
Voltage Above Normal
3563-13
Out of Calibration
3563-3
Voltage Above Normal
3563-4
Voltage Below Normal
3607-5
Current Below Normal
3607-6
Current Above Normal
3609-11
Failure Mode Not Identifiable
3609-12
Bad Device or Component
3609-5
Current Below Normal
3609-6
Current Above Normal
3619-11
Failure Mode Not Identifiable
3621-11
Failure Mode Not Identifiable
3666-5
Current Below Normal
3666-6
Current Above Normal
3709-3
Voltage Above Normal
3709-5
Current Below Normal
3709-6
Current Above Normal
3719-0
Data Valid but Above Normal Operating Range (most severe)
3719-16
Data Valid but above Normal Operating Range (moderate severity)
3742-3
Voltage Above Normal
3742-5
Current Below Normal
3742-6
Current Above Normal
3820-14
Special Instruction
3820-3
Voltage Above Normal
3820-4
Voltage Below Normal
3820-9
Abnormal Update Rate
3821-5
Current Below Normal
3821-6
Current Above Normal
3838-5
Current Below Normal
3838-6
Current Above Normal
3925-3
Voltage Above Normal
3925-4
Voltage Below Normal
3926-3
Voltage Above Normal
3926-4
Voltage Below Normal
3927-3
Voltage Above Normal
3927-4
Voltage Below Normal
3928-3
Voltage Above Normal
3928-4
Voltage Below Normal
3929-3
Voltage Above Normal
3929-4
Voltage Below Normal
3930-3
Voltage Above Normal
3930-4
Voltage Below Normal
3956-3
Voltage Above Normal
3956-4
Voltage Below Normal
3965-5
Current Below Normal
3965-6
Current Above Normal
3966-5
Current Below Normal
3966-6
Current Above Normal
4212-5
Current Below Normal
4212-6
Current Above Normal
4334-16
Data Valid but above Normal Operating Range (moderate severity)
4334-18
Data Valid But Below Normal Operating Range (moderate severity)
4334-20
Data Drifted High
4334-21
Data Drifted Low
4334-3
Voltage Above Normal
4334-4
Voltage Below Normal
4354-5
Current Below Normal
4354-6
Current Above Normal
4355-5
Current Below Normal
4355-6
Current Above Normal
4356-5
Current Below Normal
4356-6
Current Above Normal
4360-16
Data Valid but above Normal Operating Range (moderate severity)
4360-17
Data Valid But Below Normal Operating Range (least severe)
4360-18
Data Valid But Below Normal Operating Range (moderate severity)
4360-20
Data Drifted High
4360-3
Voltage Above Normal
4360-4
Voltage Below Normal
4364-18
Data Valid But Below Normal Operating Range (moderate severity)
4364-2
Data Erratic, Intermittent or Incorrect
4374-5
Current Below Normal
4374-6
Current Above Normal
4377-12
Bad Device or Component
4380-2
Data Erratic, Intermittent or Incorrect
4519-3
Voltage Above Normal
4519-4
Voltage Below Normal
4592-2
Data Erratic, Intermittent or Incorrect
4648-3
Voltage Above Normal
4648-4
Voltage Below Normal
4765-17
Data Valid But Below Normal Operating Range (least severe)
4765-3
Voltage Above Normal
4765-4
Voltage Below Normal
4783-12
Bad Device or Component
4783-21
Data Drifted Low
4783-3
Voltage Above Normal
4783-4
Voltage Below Normal
5246-0
Data Valid but Above Normal Operating Range (most severe)
5246-15
Data Valid but above Normal Operating Range (least severe)
5246-16
Data Valid but above Normal Operating Range (moderate severity)
5298-17
Data Valid But Below Normal Operating Range (least severe)
5392-31
Not Available Or Condition Exists
5571-0
Data Valid but Above Normal Operating Range (most severe)
5576-14
Special Instruction
5576-2
Data Erratic, Intermittent or Incorrect
5576-8
Abnormal Frequency, Pulse Width or Period
5578-3
Voltage Above Normal
5578-4
Voltage Below Normal
5580-0
Data Valid but Above Normal Operating Range (most severe)
5580-17
Data Valid But Below Normal Operating Range (least severe)
5580-18
Data Valid But Below Normal Operating Range (moderate severity)
5588-14
Special Instruction
5625-3
Voltage Above Normal
5625-4
Voltage Below Normal
5629-31
Not Available Or Condition Exists
5706-5
Current Below Normal
5706-6
Current Above Normal
5758-11
Failure Mode Not Identifiable
5759-11
Failure Mode Not Identifiable
5856-14
Special Instruction
5856-9
Abnormal Update Rate
5965-5
Current Below Normal
5965-6
Current Above Normal
5966-5
Current Below Normal
5966-6
Current Above Normal
6309-5
Current Below Normal
6309-6
Current Above Normal
6374-31
Not Available Or Condition Exists
6375-2
Data Erratic, Intermittent or Incorrect
6375-3
Voltage Above Normal
6375-4
Voltage Below Normal
6376-3
Voltage Above Normal
6376-4
Voltage Below Normal
6377-3
Voltage Above Normal
6377-4
Voltage Below Normal
6378-3
Voltage Above Normal
6378-5
Current Below Normal
6378-6
Current Above Normal
6379-3
Voltage Above Normal
6379-5
Current Below Normal
6379-6
Current Above Normal
6380-3
Voltage Above Normal
6380-5
Current Below Normal
6380-6
Current Above Normal
6381-3
Voltage Above Normal
6381-5
Current Below Normal
6381-6
Current Above Normal
6382-3
Voltage Above Normal
6382-4
Voltage Below Normal
6382-5
Current Below Normal
6382-6
Current Above Normal
6383-3
Voltage Above Normal
6383-4
Voltage Below Normal
6383-5
Current Below Normal
6383-6
Current Above Normal
7105-31
Not Available Or Condition Exists
7343-31
Not Available Or Condition Exists
7440-31
Not Available Or Condition Exists
7441-3
Voltage Above Normal
7441-4
Voltage Below Normal
Acceleration Is Poor or Throttle Response Is Poor
All Wheel Steer
Alternator Problem
Axle and Differential
Backup Alarm Always Off
Backup Alarm Always On
Battery Problem
Brake System
Clean Emissions Module Has High Oxygen Level
Coolant Contains Oil
Coolant Level Is Low
Coolant Temperature Is High
Coolant Temperature Is Low
Crankcase Breather Ejects Oil
Crankcase Fumes Disposal Tube Has Oil Draining
Cylinder Is Noisy
DEF Pressure Does Not Respond
DEF Pressure Is High
DEF Pressure Is Low
DEF Tank Level Is Low
DEF Tank Temperature Is High
DEF Tank Temperature Is Low
Diesel Oxidation Catalyst Has Incorrect Inlet Temperature
Diesel Oxidation Catalyst Has Low Conversion Efficiency
Diesel Particulate Filter Collects Excessive Soot (If Equipped)
Diesel Particulate Filter Temperature Is Low (If Equipped)
ECM Will Not Accept Factory Passwords
Electronic Service Tool Does Not Communicate
Engine Cranks but Does Not Start
Engine Does Not Crank
Engine Has Early Wear
Engine Has Mechanical Noise (Knock)
Engine Misfires, Runs Rough or Is Unstable
Engine Overspeeds
Engine Shutdown Occurrence
Engine Shutdown Occurs Intermittently
Engine Stalls at Low RPM
Engine Top Speed Is Not Obtained
Engine Vibration Is Excessive
Exhaust Has Excessive Black Smoke
Exhaust Has Excessive White Smoke
Exhaust System Contains Oil
Fuel Consumption Is Excessive
Fuel Contains Water
Fuel Filter Is Restricted
Fuel Pressure Is Low
Fuel Rail Pressure Problem
Fuel Temperature Is High
Hydraulic System
Inlet Air Is Restricted
Intake Manifold Air Pressure Is High
Intake Manifold Air Pressure Is Low
Intake Manifold Air Temperature Is High
NOx Conversion Is Low
NRS Exhaust Gas Temperature Is High
NRS Mass Flow Rate Problem
Oil Consumption Is Excessive
Oil Contains Coolant
Oil Contains Fuel
Oil Level Is Low
Oil Pressure Is Low
Power Is Intermittently Low or Power Cutout Is Intermittent
Power Train Troubleshooting
SCR Catalyst Has Incorrect Inlet Temperature
SCR Warning System Problem
Steering System
Transmission
Valve Lash Is Excessive