Coduri de eroare Caterpillar® (CAT®) · Pe utilaj
164 de coduri de eroare documentate pentru C27 Petroleum Gen Set (familia Produse petroliere). Alege codul de pe afișaj pentru diagnostic și piese.
1-5
Current Below Normal
1-6
Current Above Normal
2-5
Current Below Normal
2-6
Current Above Normal
3-5
Current Below Normal
3-6
Current Above Normal
4-5
Current Below Normal
4-6
Current Above Normal
5-5
Current Below Normal
5-6
Current Above Normal
6-5
Current Below Normal
6-6
Current Above Normal
7-5
Current Below Normal
7-6
Current Above Normal
8-5
Current Below Normal
8-6
Current Above Normal
9-5
Current Below Normal
9-6
Current Above Normal
10-5
Current Below Normal
10-6
Current Above Normal
11-5
Current Below Normal
11-6
Current Above Normal
12-5
Current Below Normal
12-6
Current Above Normal
16-1
Data Valid But Below Normal Operating Range (most severe)
16-17
Data Valid But Below Normal Operating Range (least severe)
16-19
Received Network Data In Erro
57
59
91-8
Abnormal Frequency, Pulse Width or Period
94-0
Data Valid but Above Normal Operating Range (most severe)
94-1
Data Valid But Below Normal Operating Range (most severe)
94-15
Data Valid but above Normal Operating Range (least severe)
94-16
Data Valid but above Normal Operating Range (moderate severity)
94-17
Data Valid But Below Normal Operating Range (least severe)
94-18
Data Valid But Below Normal Operating Range (moderate severity)
94-3
Voltage Above Normal
94-4
Voltage Below Normal
96
100-1
Data Valid But Below Normal Operating Range (most severe)
100-10
Abnormal rate of change
100-17
Data Valid But Below Normal Operating Range (least severe)
100-3
Voltage Above Normal
100-4
Voltage Below Normal
108-3
Voltage Above Normal
108-4
Voltage Below Normal
110-0
Data Valid but Above Normal Operating Range (most severe)
110-15
Data Valid but above Normal Operating Range (least severe)
110-16
Data Valid but above Normal Operating Range (moderate severity)
110-3
Voltage Above Normal
110-4
Voltage Below Normal
111-17
Data Valid But Below Normal Operating Range (least severe)
111-18
Data Valid But Below Normal Operating Range (moderate severity)
168-0
Data Valid but Above Normal Operating Range (most severe)
168-1
Data Valid But Below Normal Operating Range (most severe)
168-2
Data Erratic, Intermittent or Incorrect
172-3
Voltage Above Normal
172-4
Voltage Below Normal
173-15
Data Valid but above Normal Operating Range (least severe)
174-0
Data Valid but Above Normal Operating Range (most severe)
174-15
Data Valid but above Normal Operating Range (least severe)
174-16
Data Valid but above Normal Operating Range (moderate severity)
174-3
Voltage Above Normal
174-4
Voltage Below Normal
175-0
Data Valid but Above Normal Operating Range (most severe)
175-15
Data Valid but above Normal Operating Range (least severe)
175-16
Data Valid but above Normal Operating Range (moderate severity)
175-3
Voltage Above Normal
175-4
Voltage Below Normal
190-0
Data Valid but Above Normal Operating Range (most severe)
190-15
Data Valid but above Normal Operating Range (least severe)
190-8
Abnormal Frequency, Pulse Width or Period
194
197
198
228-11
Failure Mode Not Identifiable
228-13
Out of Calibration
234-2
Data Erratic, Intermittent or Incorrect
247-9
Abnormal Update Rate
253-2
Data Erratic, Intermittent or Incorrect
261-11
Failure Mode Not Identifiable
261-13
Out of Calibration
262-3
Voltage Above Normal
262-4
Voltage Below Normal
264
268-2
Data Erratic, Intermittent or Incorrect
274-3
Voltage Above Normal
274-4
Voltage Below Normal
342-8
Abnormal Frequency, Pulse Width or Period
360
361
362
363
390
444-5
Current Below Normal
444-6
Current Above Normal
446-5
Current Below Normal
446-6
Current Above Normal
539
620-3
Voltage Above Normal
620-4
Voltage Below Normal
651-5
Current Below Normal
651-6
Current Above Normal
652-5
Current Below Normal
652-6
Current Above Normal
653-5
Current Below Normal
653-6
Current Above Normal
654-5
Current Below Normal
654-6
Current Above Normal
655-5
Current Below Normal
655-6
Current Above Normal
656-5
Current Below Normal
656-6
Current Above Normal
657-5
Current Below Normal
657-6
Current Above Normal
658-5
Current Below Normal
658-6
Current Above Normal
659-5
Current Below Normal
659-6
Current Above Normal
660-5
Current Below Normal
660-6
Current Above Normal
661-5
Current Below Normal
661-6
Current Above Normal
662-5
Current Below Normal
662-6
Current Above Normal
723-8
Abnormal Frequency, Pulse Width or Period
970-31
Not Available Or Condition Exists
1111-2
Data Erratic, Intermittent or Incorrect
1636-15
Data Valid but above Normal Operating Range (least severe)
1636-16
Data Valid but above Normal Operating Range (moderate severity)
1785-10
Abnormal rate of change
1785-3
Voltage Above Normal
1785-4
Voltage Below Normal
2087
2088
4000-31
Not Available Or Condition Exists
Alternator - Charging Problem
Can Not Reach Top Engine RPM
Coolant in Engine Oil
ECM Will Not Accept Factory Passwords
ECM Will Not Communicate with Other Systems or Display Modules
Electronic Service Tool Will Not Communicate with ECM
Engine Cranks but Will Not Start
Engine Has Early Wear
Engine Misfires, Runs Rough or Is Unstable
Engine Oil in Cooling System
Engine Stalls at Low RPM
Engine Vibration
Engine Will Not Crank
Excessive Black Smoke
Excessive Engine Oil Consumption
Excessive Fuel Consumption
Excessive Valve Lash
Excessive White Smoke
Fuel Dilution of Engine Oil
Fuel in Cooling System
Intermittent Engine Shutdown
Intermittent Low Power or Power Cutout
Low Engine Oil Pressure
Low Power/Poor or No Response to Throttle
Mechanical Noise (Knock) in Engine
Noise Coming from Cylinder
Poor Acceleration or Response
Valve Rotator or Spring Lock Is Free