0 - Disabled
1-5
Current Below Normal
1-6
Current Above Normal
1 - Not evaluated
2-5
2-6
3-5
3-6
4-5
4-6
5-5
5-6
6-5
6-6
41-3
Voltage Above Normal
41-4
Voltage Below Normal
42-5
42-6
64 - OK
91-2
Data Erratic, Intermittent or Incorrect
94-3
94-4
96
100-10
Abnormal rate of change
100-3
100-4
110-3
110-4
128 - High temperature
129 - Low supply voltage
130 - High supply voltage
131 - Date and time not set
132 - Start block
133 - Low Alarm
134 - High Alarm
135 - Saturated
137 - Checksum error
164-11
Failure Mode Not Identifiable
164-3
164-4
168-0
Data Valid but Above Normal Operating Range (most severe)
168-1
Data Valid But Below Normal Operating Range (most severe)
168-2
172
172-3
172-4
190-8
Abnormal Frequency, Pulse Width or Period
192 - Low error
193 - High error
194
194 - Overload
195 - Open load
196 - Division by zero
197 - Calculation overflow
198
198 - Negative square root
199 - Invalid argument
200 - J1939 error
201 - J1939 not available
202 - Timeout
203 - No contact
204 - Multiple address
205 - VREF error
206 - Internal error
207 - Critical error
208 - Pin conflict
209 - CAN bus error
210 - Address error
211 - Out of range
212 - Input error
213 - Diff check error
241
247-12
Bad Device or Component
247-9
Abnormal Update Rate
253-2
261-13
Out of Calibration
262-3
262-4
264-8
266-2
268-2
274-3
274-4
291-5
291-6
296-12
296-9
342-8
360
361
362
539
544-2
544-8
1589-3
1589-4
1599-5
1599-6
1600-5
1600-6
1639-2
1639-9
1785-10
1785-3
1785-4
Air Conditioning System Troubleshooting
Alternator (Charging Problem and/or Noisy Operation)
Automatic Temperature Control Panel Troubleshooting (584 and 584HDForwarders)
Automatic Temperature Control System (ECM Controlled) Troubleshooting
Battery
CAN-H open circuit
CAN-H to -BAT
CAN-L open circuit
CAN-L to -BAT
CAN-L to CAN-H
CAN-termination failure, termination off
CAN-termination failure, termination on
Can Not Reach Top Engine RPM
Coolant in Engine Oil
Coolant Temperature Is Too High
COUT Open
COUT shorted to -BAT
COUT shorted to 2:nd COUT (passive)
COUT shorted to 2:nd RET (active)
COUT shorted to 2:nd RET (passive)
COUT shorted to RET (active)
COUT shorted to RET (passive)
DFIN Open
DFIN shorted to -BAT
DIN Open
DIN shorted to -BAT
ECM Will Not Accept Factory Passwords
ECM Will Not Communicate with Other Systems or Display Modules
Electronic Service Tool Will Not Communicate with ECM
Engine Cranks but Will Not Start
Engine Has Early Wear
Engine Misfires, Runs Rough or Is Unstable
Engine Oil in Cooling System
Engine Oil Temperature Is Too High
Engine Stalls at Low RPM
Engine Vibration
Engine Will Not Crank
Excessive Black Smoke
Excessive Engine Oil Consumption
Excessive Fuel Consumption
Excessive Valve Lash
Excessive White Smoke
Exhaust Temperature Is Too High
FAN_SPEED Open
FAN_SPEED shorted to -FAN
FAN_SPEED shorted to heatsink
Fan jammed
-FAN Open
+FAN shorted to - FAN
-FAN shorted to heatsink
FIN Open
FIN shorted to -BAT
Fuel Dilution of Engine Oil
Fuel in Cooling System
H-side Open
H-side shorted to -BAT
H-side shorted to 2:nd L-side (active)
H-side shorted to 2:nd L-side (passive)
H-side shorted to L-side (active)
H-side shorted to L-side (passive)
Heating System Troubleshooting
High internal temperature due to high ambient temperature
High internal temperature due to jammed fan
Hydraulic System Troubleshooting
Insufficient voltage
Intermittent Engine Shutdown
Intermittent Low Power or Power Cutout
IQAN Error Messages and Warnings
L-side (active) Open
L-side (active) shorted to -BAT
L-side (passive) Open
L-side (passive) shorted to -BAT
L-side shorted to 2:nd L-side (active)
L-side shorted to 2:nd L-side (passive)
Low Engine Oil Pressure
Low Power/Poor or No Response to Throttle
Mechanical Noise (Knock) in Engine
Noise Coming from Cylinder
Poor Acceleration or Response
Preheater Troubleshooting
RET (active) Open
RET (active) shorted to -BAT
RET (passive) Open
RET (passive) shorted to -BAT
RET shorted to 2:nd RET (active)
RET shorted to 2:nd RET (passive)
Troubleshooting Condensate Drainage System
Troubleshooting Heating and Air Conditioning Control System
VIN Open
VIN shorted to -BAT
-VREF Open
-VREF shorted to -BAT
+VREF shorted to -VREF